AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular | Open Access

Graphene Oxide Functionalized Optical Planar Waveguide for Water Content Measurement in Alcohol

Wenghong LIM1, Yuenkiat YAP1,2, Choonkong LAI1, Wuyi CHONG1( ), Harith AHMAD1,3
Photonics Research Centre, University of Malaya, Kuala Lumpur 50603, Malaysia
Heriot-Watt University Malaysia, Putrajaya 62200, Malaysia
Department of Physics, Faculty of Science, University of Malaya, Kuala Lumpur 50603, Malaysia
Show Author Information

Abstract

An abrupt change in optical transmission characteristic of a graphene oxide (GO) coated optical planar waveguide was observed. This observation was based on the peculiar characteristics of the graphene oxide film, namely its high transverse-electric polarized light propagation loss, highly selective permeability of water, and change in optical propagation characteristic in the presence of water. The as-fabricated GO-coated optical waveguide showed a large polarization dependent loss of ~32dB in the C-band optical fiber communication window (1550nm). The response of the proposed sensor was first tested by using water. When a drop of water was applied onto the GO coating, the large polarization dependent loss was fully suppressed almost instantaneously. This effect was reversible as the polarization dependent loss was restored after complete water evaporation from the GO coating. All-optical measurement of water content in alcohol was then demonstrated by using the GO-coated optical waveguide. By analyzing the drying profile of the water-alcohol mixture, water content in the range of 0.2volume% – 100volume% could be measured. These measurements were carried out by using solution volume of 1.0μL only. The all-optical sensing nature of the proposed sensor has potential applications in in-situ monitoring of water content in alcohol.

References

【1】
【1】
 
 
Photonic Sensors
Pages 215-222

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LIM W, YAP Y, LAI C, et al. Graphene Oxide Functionalized Optical Planar Waveguide for Water Content Measurement in Alcohol. Photonic Sensors, 2020, 10(3): 215-222. https://doi.org/10.1007/s13320-020-0584-3

459

Views

1

Crossref

N/A

Web of Science

2

Scopus

0

CSCD

Received: 10 May 2019
Revised: 07 November 2019
Published: 28 May 2020
© The Author(s) 2020.

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.