An Extrinsic Fiber Fabry-Perot Interferometer for Dynamic Displacement Measurement

S. PULLTEAP1( )H. C. SEAT2
Department of Mechanical Engineering, Faculty of Engineering and Industrial Technology, Silpakorn University (Sanam Chandra Palace Campus), Nakhon Pathom, 73000, Thailand
Optoelectronics for Embedded Systems Group, INPT-ENSEEIHT, Rue Charles Camichel, BP 7122-31071 Toulouse Cedex7, France
Show Author Information

Abstract

A versatile fiber interferometer was proposed for high precision measurement. The sensor exploited a double-cavity within the unique sensing arm of an extrinsic-type fiber Fabry-Perot interferometer to produce the quadrature phase-shifted interference fringes. Interference signal processing was carried out using a modified zero-crossing (fringe) counting technique to demodulate two sets of fringes. The fiber interferometer has been successfully employed for dynamic displacement measurement under different displacement profiles over a range of 0.7 μm to 140 μm. A dedicated computer incorporating the demodulation algorithm was next used to interpret these detected data as well as plot the displacement information with a resolution of λ/64. A commercial displacement sensor was employed for comparison purposes with the experimental data obtained from the fiber interferometer as well as to gauge its performance, resulting in the maximum error of 2.8% over the entire displacement range studied.

References

【1】
【1】
 
 
Photonic Sensors
Pages 50-59

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
PULLTEAP S, SEAT HC. An Extrinsic Fiber Fabry-Perot Interferometer for Dynamic Displacement Measurement. Photonic Sensors, 2015, 5(1): 50-59. https://doi.org/10.1007/s13320-014-0209-9

235

Views

18

Downloads

10

Crossref

N/A

Web of Science

14

Scopus

0

CSCD

Received: 02 July 2014
Revised: 20 November 2014
Published: 15 December 2014
© The Author(s) 2014.

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.