Comparison Study of Two Commercial Spectrometers for Heavy Metal Analysis of Laser Induced Breakdown Spectroscopy (LIBS)

M. ARABN. BIDIN( )Z. H. RIZVIS. SAFIEM. A. ALSAEDI
Advance Photonics Science Institute, Faculty of Science, Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia
Show Author Information

Abstract

The purpose of this paper is to compare the performance of two spectrometers that are manufactured from the same company. In this work, heavy metals like lead Pb and copper Cu in the KBr matrix were analyzed using the laser induced breakdown spectroscopic technique. A Q-switched Nd:YAG laser with 90 mJ per pulse operating at the fundamental wavelength of 1064 nm and pulse duration of 10 ns was used to generate plasma at the focal region. The important experimental parameters such as the laser energy, integration time, distance between the lens and sample, distance and angle of the optical fiber from the target were optimized. Two spectrometers manufactured by Ocean Optics namely as Maya2000Pro and USB 4000 were employed for anlyzing the spectral lines. The experimental setup and conditions were remained the same for both experiments. The production of spectral lines from each of the interested elements was analyzed and compared with the NIST (National Institute of Standards and Technology) database. The sensitivity, repeatability and limit of detection for each of the systems are discussed in detail.

References

【1】
【1】
 
 
Photonic Sensors
Pages 63-69

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ARAB M, BIDIN N, RIZVI ZH, et al. Comparison Study of Two Commercial Spectrometers for Heavy Metal Analysis of Laser Induced Breakdown Spectroscopy (LIBS). Photonic Sensors, 2014, 4(1): 63-69. https://doi.org/10.1007/s13320-013-0144-1

246

Views

22

Downloads

8

Crossref

N/A

Web of Science

12

Scopus

0

CSCD

Received: 10 September 2013
Revised: 22 November 2013
Published: 03 January 2014
© The Author(s) 2013.

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.