Research Article

A gold-based multiplex immunochromatographic sensor for detecting paclitaxel, methotrexate, and 5-fluorouracil in clinical samples

Xiaoqian Jiang1,2Aihua Qu1,2 ( )Xinxin Xu1,2Hua Kuang1,2Liqiang Liu1,2Chuanlai Xu1,2( )
State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi 214122, China
International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
Show Author Information

Abstract

Paclitaxel (PTX), methotrexate (MTX), and 5-fluorouracil (5-FU) are commonly-used small molecule anti-tumor drugs for breast cancer. Unfortunately, drug resistance occurs with long-term treatment or excessive use, and the high concentrations of PTX, MTX, and 5-FU in patients may lead to side effects with dose-limiting toxicities, such as myelosuppression, hepatotoxicity, and peripheral neuropathy. Therefore, concentration monitoring of PTX, MTX, and 5-FU in clinical treatment is very important. We prepared highly sensitive and specific monoclonal antibodies using several haptens, and established a multiple paper-based sensor utilizing optical signals of gold nanoparticles, which simultaneously detected PTX, MTX, and 5-FU in human plasma or urine with 10 min. A portable scanner for quantitative detection in plasma and urine samples was used, and the calculated limit of detection (cLOD) values were 0.002 and 0.142 μg/mL for PTX, 0.187 and 0.976 ng/mL for MTX, and 0.057 and 0.128 μg/mL for 5-FU, respectively. In the recovery test, the recovery rates and the coefficient of variation were 85.84%–108.81% and 1.23%–8.80%, respectively, indicating the reliability and accuracy of the multiple gold immunochromatographic strip (GIS). In addition, for the determination of collected clinical plasma samples, the correlation between the test data of the multiple GIS and liquid chromatography–tandem mass spectrometry (LC–MS/MS) was good. Therefore, the developed multiple GIS could be applied to the rapid detection of PTX, MTX, and 5-FU in different clinical samples.

Graphical Abstract

Monoclonal antibodies against paclitaxel (PTX) and methotrexate (MTX) were developed and a gold-based multiplex immunochromatographic strip was established for simultaneously detecting PTX, MTX, and 5-fluorouracil (5-FU).

Electronic Supplementary Material

Download File(s)
6649_ESM.pdf (1.1 MB)

References

【1】
【1】
 
 
Nano Research
Pages 6420-6429

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Jiang X, Qu A, Xu X, et al. A gold-based multiplex immunochromatographic sensor for detecting paclitaxel, methotrexate, and 5-fluorouracil in clinical samples. Nano Research, 2024, 17(7): 6420-6429. https://doi.org/10.1007/s12274-024-6649-7
Topics:

1493

Views

116

Downloads

6

Crossref

6

Web of Science

7

Scopus

0

CSCD

Received: 15 February 2024
Revised: 10 March 2024
Accepted: 21 March 2024
Published: 06 April 2024
© Tsinghua University Press 2024