AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

SERS-based lateral flow immunoassay of troponin I by using gap-enhanced Raman tags

Boris N. Khlebtsov1,2( )Daniil N. Bratashov2Nadezhda A. Byzova3Boris B. Dzantiev3Nikolai G. Khlebtsov1,2( )
Institute of Biochemistry and Physiology of Plants and Microorganisms,Russian Academy of Sciences,Saratov,410049,Russia;
Saratov State University,Saratov,410012,Russia;
A. N. Bach Institute of Biochemistry,Research Centre of Biotechnology, Russian Academy of Sciences,Moscow,119071,Russia;
Show Author Information

Abstract

The lateral flow immunoassay (LFIA) has emerged as a powerful tool for rapid screening owing to its simplicity and flexibility for detection of various biomarkers. However, conventional LFIA strips have several disadvantages, including limits in quantitative analysis and low sensitivity. Here we developed a novel surface-enhanced Raman scattering LFIA based on nonspherical gap-enhanced Raman tags (GERTs), with Raman molecules (RMs) embedded in a 1-nm gap between Au nanorod core and Au shell. Such tags have a strong and uniform surface-enhanced Raman scattering (SERS) response, an order of magnitude higher than that of other common SERS tags such as Au nanorods, nanostars, Au nanoshells with surface-adsorbed RMs, or spherical GERTs with embedded RMs. The feasibility of the tags was demonstrated by the semiquantitative and sensitive detection of the heart disease biomarker cardiac troponin I (cTnI). GERTs were conjugated with monoclonal antibodies and used for LFIA in the same way as ordinary functionalized colloidal gold. The presence of the target antigen, cTnI, was identified by Raman microscopy mapping of the test zone. With the SERS-based LFIA, the limit of cTnI detection was about 0.1 ng/mL. This value is within the diagnostic range of cTnI in the blood serum of patients with heart infarction and is 30 times lower than that of the colorimetric LFIA test using the same antibodies and either GERTs or colloidal gold as labels.

Graphical Abstract

Electronic Supplementary Material

Download File(s)
12274_2018_2232_MOESM1_ESM.pdf (13.3 MB)

References

【1】
【1】
 
 
Nano Research
Pages 413-420

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Khlebtsov BN, Bratashov DN, Byzova NA, et al. SERS-based lateral flow immunoassay of troponin I by using gap-enhanced Raman tags. Nano Research, 2019, 12(2): 413-420. https://doi.org/10.1007/s12274-018-2232-4
Topics:

1754

Views

141

Crossref

N/A

Web of Science

146

Scopus

8

CSCD

Received: 09 June 2018
Revised: 18 October 2018
Accepted: 19 October 2018
Published: 19 November 2018
© Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2018