AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Extraction, detection, and profiling of serum biomarkers using designed Fe3O4@SiO2@HA core–shell particles

Chandrababu Rejeeth1,§, Xuechao Pang1,§, Ru Zhang1, Wei Xu1, Xuming Sun1, Bin Liu1, Jiatao Lou1, Jingjing Wan2, Hongchen Gu1, Wei Yan1( ), Kun Qian1( )
School of Biomedical EngineeringShanghai Center for System BiomedicineShanghai Chest Hospitaland Med-X Research InstituteShanghai Jiao Tong UniversityShanghai200030China
Department of ChemistryShanghai UniversityShanghai200444China

§Chandrababu Rejeeth and Xuechao Pang contributed equally to this work.

Show Author Information

Abstract

Serum biomarkers in the form of proteins (e.g. cluster of differentiation-44 (CD44)) have been demonstrated to have high clinical sensitivity and specificity for disease diagnosis and prognosis. Owing to the high sample complexity and low molecular abundance in serum, the detection and profiling of biomarkers rely on efficient extraction by materials and devices, mostly using immunoassays via antibody-antigen recognition. Antibody-free approaches are promising and need to be developed for real-case applications in serum to address the limitations of antibody-based techniques in terms of robustness, expense, and throughput. In this work, we demonstrated a novel approach using hyaluronic acid (HA)-modified materials/devices for the extraction, detection, and profiling of serum biomarkers via ligand-protein interactions. We constructed Fe3O4@SiO2@HA particles with different sizes through layer-by-layer assembly and for the first time applied HA-functionalized particles in the facile extraction and sequence identification of CD44 in serum by mass spectrometry. We also first validated HA-CD44 binding through electrochemical sensing using HA-modified electrodes in both standard solutions and diluted serum samples, achieving a detection limit of ~0.6 ng/mL and a linear response range from 1 ng/mL to 10 μg/mL. Furthermore, we performed profiling of HA-binding serum proteome, providing a new preliminary benchmark for the construction of future databases, and we investigated selected surface chemistries of particles for the capture of proteins in serum. Our work not only resulted in the development of a platform technology for CD44 extraction/detection and HA-binding proteome identification, but also guided the design of ligand affinity-based approaches for antibody-free analysis of serum biomarkers towards diagnostic applications.

Graphical Abstract

Electronic Supplementary Material

Download File(s)
nr-11-1-68_ESM.pdf (7.5 MB)

References

【1】
【1】
 
 
Nano Research
Pages 68-79

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Rejeeth C, Pang X, Zhang R, et al. Extraction, detection, and profiling of serum biomarkers using designed Fe3O4@SiO2@HA core–shell particles. Nano Research, 2018, 11(1): 68-79. https://doi.org/10.1007/s12274-017-1591-6

1402

Views

68

Crossref

N/A

Web of Science

67

Scopus

0

CSCD

Received: 08 December 2016
Revised: 06 March 2017
Accepted: 09 March 2017
Published: 05 August 2017
© Tsinghua University Press and Springer-Verlag GmbH Germany 2017