AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Quality assessment of graphene: Continuity, uniformity, and accuracy of mobility measurements

David M. A. Mackenzie1,2( ), Jonas D. Buron1,2, Patrick R. Whelan1,2, José M. Caridad1,2, Martin Bjergfelt1,2, Birong Luo1,2, Abhay Shivayogimath1,2, Anne L. Smitshuysen1,2, Joachim D. Thomsen1,2, Timothy J. Booth1,2, Lene Gammelgaard1,2, Johanna Zultak1,2, Bjarke S. Jessen1,2, Peter Bøggild1,2, Dirch H. Petersen1,2
Department of Micro- and NanotechnologyTechnical University of Denmark, Ørsteds Plads 345 BKongens Lyngby2800Denmark
Center for Nanostructured Graphene (CNG)Technical University of DenmarkKongens Lyngby2800Denmark
Show Author Information

Abstract

With the increasing availability of large-area graphene, the ability to rapidly and accurately assess the quality of the electrical properties has become critically important. For practical applications, spatial variability in carrier density and carrier mobility must be controlled and minimized. We present a simple framework for assessing the quality and homogeneity of large-area graphene devices. The field effect in both exfoliated graphene devices encapsulated in hexagonal boron nitride and chemical vapor-deposited (CVD) devices was measured in dual current–voltage configurations and used to derive a single, gate-dependent effective shape factor, β, for each device. β is a sensitive indicator of spatial homogeneity that can be obtained from samples of arbitrary shape. All 50 devices investigated in this study show a variation (up to tenfold) in β as a function of the gate bias. Finite element simulations suggest that spatial doping inhomogeneity, rather than mobility inhomogeneity, is the primary cause of the gate dependence of β, and that measurable variations of β can be caused by doping variations as small as 1010 cm-2. Our results suggest that local variations in the position of the Dirac point alter the current flow and thus the effective sample shape as a function of the gate bias. We also found that such variations lead to systematic errors in carrier mobility calculations, which can be revealed by inspecting the corresponding β factor.

Graphical Abstract

Electronic Supplementary Material

Download File(s)
nr-10-10-3596_ESM.pdf (1.7 MB)

References

【1】
【1】
 
 
Nano Research
Pages 3596-3605

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Mackenzie DMA, Buron JD, Whelan PR, et al. Quality assessment of graphene: Continuity, uniformity, and accuracy of mobility measurements. Nano Research, 2017, 10(10): 3596-3605. https://doi.org/10.1007/s12274-017-1570-y

1274

Views

35

Crossref

N/A

Web of Science

34

Scopus

0

CSCD

Received: 30 November 2016
Revised: 02 March 2017
Accepted: 04 March 2017
Published: 04 July 2017
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2017