AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Direct detection and measurement of wall shear stress using a filamentous bio-nanoparticle

Daniela P. Lobo1, Alan M. Wemyss1,2, David J. Smith3, Anne Straube4, Kai B. Betteridge5, Andrew H. J. Salmon5, Rebecca R. Foster6, Hesham E. Elhegni6, Simon C. Satchell6, Haydn A. Little7, Raúl Pacheco-Gómez8, Mark J. Simmons9, Matthew R. Hicks8, David O. Bates10, Alison Rodger1( ), Timothy R. Dafforn8, Kenton P. Arkill11
Department of Chemistry and Warwick Analytical Science CentreUniversity of WarwickCoventryCV4 7ALUK
MOAC Doctoral Training CentreUniversity of WarwickCoventryCV4 7ALUK
Mathematics, University of BirminghamEdgbaston, BirminghamWest MidlandsB15 2TTUK
Centre for Mechanochemical Cell BiologyWarwick Medical School, University of WarwickCoventryCV4 7ALUK
Physiology and PharmacologyUniversity of Bristol, University WalkBristolBS8 1TDUK
Clinical SciencesWhitson Street, University of BristolBristolBS1 3NYUK
School of Chemistry, University of BirminghamEdgbaston, BirminghamWest MidlandsB15 2TTUK
Biosciences, University of BirminghamEdgbaston, BirminghamWest MidlandsB15 2TTUK
Chemical Engineering, University of BirminghamEdgbaston, BirminghamWest MidlandsB15 2TTUK
School of Medicine, University of NottinghamQueen's Medical CentreNottinghamNG2 7UHUK
Biochemistry, University of BristolUniversity WalkBristolBS8 1TDUK
Show Author Information

Abstract

The wall shear stress (WSS) that a moving fluid exerts on a surface affects many processes including those relating to vascular function. WSS plays an important role in normal physiology (e.g. angiogenesis) and affects the microvasculature's primary function of molecular transport. Points of fluctuating WSS show abnormalities in a number of diseases; however, there is no established technique for measuring WSS directly in physiological systems. All current methods rely on estimates obtained from measured velocity gradients in bulk flow data. In this work, we report a nanosensor that can directly measure WSS in microfluidic chambers with sub-micron spatial resolution by using a specific type of virus, the bacteriophage M13, which has been fluorescently labeled and anchored to a surface. It is demonstrated that the nanosensor can be calibrated and adapted for biological tissue, revealing WSS in micro-domains of cells that cannot be calculated accurately from bulk flow measurements. This method lends itself to a platform applicable to many applications in biology and microfluidics.

Graphical Abstract

Electronic Supplementary Material

Download File(s)
nr-8-10-3307_ESM.pdf (764.5 KB)

References

【1】
【1】
 
 
Nano Research
Pages 3307-3315

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Lobo DP, Wemyss AM, Smith DJ, et al. Direct detection and measurement of wall shear stress using a filamentous bio-nanoparticle. Nano Research, 2015, 8(10): 3307-3315. https://doi.org/10.1007/s12274-015-0831-x

1363

Views

63

Downloads

8

Crossref

N/A

Web of Science

7

Scopus

0

CSCD

Received: 19 February 2015
Revised: 04 June 2015
Accepted: 08 June 2015
Published: 25 August 2015
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2015