AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Article Link
Collect
Submit Manuscript
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Optical mesoscopic membrane sensor layouts for water-free and blood-free toxicants

Sherif A. El-Safty1,2( ), Mohamed Khairy1, Mohamed A. Shenashen1, Emad Elshehy1, Wojciech Warkocki1, Masaru Sakai3
National Institute for Materials Science (NIMS)1-2-1 Sengen, Tsukuba-shiIbaraki305-0047Japan
Graduate School for Science and EngineeringWaseda University, 3-4-1 Okubo, Shinjuku-kuTokyo169-8555Japan
Center for Research in Isotopes and Environmental DynamicsTsukuba University, 1-1-1 Tennodai, TsukubaIbaraki305-8572Japan
Show Author Information

Abstract

Advances in fabrication of mesoscopic membrane sensors with unique structures and morphologies inside anodic alumina membrane (AAM) nanochannels have led to the development of various methods for detecting, visualizing, adsorbing, filtering, and recovering ultra-trace concentrations of toxic metal ions, such as Hg2+ and Pb2+, in water and blood. These often "one-pot" screening methods offer advantages over conventional methods in that they do not require sophisticated instruments or laborious sample preparation. In the present study, we fabricated two mesoscopic membrane sensors for naked-eye detection, recognition, filtration, and recovery of Hg2+ and Pb2+ in biological and environmental samples. These sensors were characterized by the dense immobilization of organic colorants on the mesopore surfaces of silica nanotubes that were constructed using the nanochannels of an AAM as a scaffold. We confirmed that the nanotubes were oriented along the long axis of the AAM nanochannels, open at both ends, and completely and uniformly filled with organic colorants; also, the dense immobilization of the organic colorants did not affect the speed of ion-to-ligand binding events. We used simple, desk-top, flow-through assays to assess the suitability of the developed membrane sensors for detection, removal, and filtration of Hg2+ and Pb2+ with respect to recyclability and continuous monitoring. Removal of the target ions from biological fluids was assessed by means of flow cytometric analysis. Our results demonstrate the potential of our membrane sensors to be used for preventing the health risks associated with exposure to toxic metal ions in the environment and blood.

Graphical Abstract

Electronic Supplementary Material

Download File(s)
nr-8-10-3150_ESM.pdf (3.6 MB)

References

【1】
【1】
 
 
Nano Research
Pages 3150-3163

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
El-Safty SA, Khairy M, Shenashen MA, et al. Optical mesoscopic membrane sensor layouts for water-free and blood-free toxicants. Nano Research, 2015, 8(10): 3150-3163. https://doi.org/10.1007/s12274-015-0815-x

1094

Views

53

Crossref

N/A

Web of Science

51

Scopus

1

CSCD

Received: 19 February 2015
Revised: 11 May 2015
Accepted: 12 May 2015
Published: 19 August 2015
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2015