AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article

Biological imaging without autofluorescence in the second near-infrared region

Shuo Diao1,§Guosong Hong1,,§Alexander L. Antaris1,§Jeffrey L. Blackburn2Kai Cheng3Zhen Cheng3Hongjie Dai1( )
Department of ChemistryStanford UniversityStanford, California94305USA
Chemical and Materials Science CenterNational Renewable Energy LaboratoryColorado80401USA
Molecular Imaging Program at Stanford (MIPS) and Department of RadiologyStanford UniversityStanford, California94305USA

§ These authors contributed to the work equally.

Present address: Department of Chemistry and Chemical Biology, Harvard University, Massachusetts 02138, USA

Show Author Information

Abstract

Fluorescence imaging is capable of acquiring anatomical and functional information with high spatial and temporal resolution. This imaging technique has been indispensable in biological research and disease detection/diagnosis. Imaging in the visible and to a lesser degree, in the near-infrared (NIR) regions below 900 nm, suffers from autofluorescence arising from endogenous fluorescent molecules in biological tissues. This autofluorescence interferes with fluorescent molecules of interest, causing a high background and low detection sensitivity. Here, we report that fluorescence imaging in the 1, 500–1, 700-nm region (termed "NIR-Ⅱb") under 808-nm excitation results in nearly zero tissue autofluorescence, allowing for background-free imaging of fluorescent species in otherwise notoriously autofluorescent biological tissues, including liver. Imaging of the intrinsic fluorescence of individual fluorophores, such as a single carbon nanotube, can be readily achieved with high sensitivity and without autofluorescence background in mouse liver within the 1, 500–1, 700-nm wavelength region.

Graphical Abstract

Electronic Supplementary Material

Download File(s)
nr-8-9-3027_ESM.pdf (747.4 KB)

References

【1】
【1】
 
 
Nano Research
Pages 3027-3034

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Diao S, Hong G, Antaris AL, et al. Biological imaging without autofluorescence in the second near-infrared region. Nano Research, 2015, 8(9): 3027-3034. https://doi.org/10.1007/s12274-015-0808-9

1633

Views

99

Downloads

332

Crossref

N/A

Web of Science

331

Scopus

33

CSCD

Received: 15 January 2015
Revised: 27 April 2015
Accepted: 30 April 2015
Published: 14 August 2015
© Tsinghua University Press and Springer-Verlag Berlin Heidelberg 2015