Effect of Driver Material Properties and Excitation Frequencies on Quantitative Myocardial Stiffness Measurements in Magnetic Resonance Elastography

Yong Cheng1, Jun Wang1, Shuangshuang Xu1, Zijun Zheng1, Yewen Jiang1, Peiyang Zheng2, Shutian An1, Zhanglei Li1, Jun Chen3, Kiaran P. McGee3, Yongqiang Yu1, Ren Zhao2( ), Xiaohu Li1 ( )
Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Research Center of Clinical Medical Imaging, Anhui Province Clinical Image Quality Control Center, Hefei, China
Department of Cardiology, The First Affiliated Hospital of Anhui Medical University, Hefei, China
Department of Radiology, Mayo Clinic, Rochester, New York, USA

Yong Cheng, Jun Wang and Shuangshuang Xu contributed equally to this work.

Show Author Information

Abstract

Background

Myocardial stiffness is a crucial indicator of cardiac function and is associated with various cardiovascular diseases. Magnetic resonance elastography (MRE) is a noninvasive imaging technique used to measure myocardial stiffness. However, the effects of driver material properties and excitation frequencies on MRE performance remain unclear. This study investigated the influence of different driver materials and excitation frequencies on myocardial stiffness measurements and signal quality.

Methods

This prospective study included 13 healthy adults (four women and nine men) without known cardiac disease. MRE was performed on a 3.0‐T magnetic resonance imaging system using two different driver materials (flexible and rigid) at two frequencies (80 and 140 Hz). Myocardial stiffness and octahedral shear strain signal‐to‐noise ratio (OSS‐SNR) were quantified. Paired t‐test, intraclass correlation coefficient, and Bland–Altman analysis were used for statistical analysis.

Results

At 80 Hz, the flexible driver yielded significantly higher stiffness values and OSS‐SNR than the rigid driver (all p < 0.01). At 140 Hz, the two drivers resulted in similar stiffness values; however, the rigid driver yielded a significantly higher OSS‐SNR (p = 0.007). A significant increase in stiffness was observed at 140 Hz compared with that at 80 Hz (p < 0.001).

Conclusions

Owing to its superior signal quality, the flexible driver may be more suitable for low‐frequency (80 Hz) MRE. Meanwhile, the rigid driver may exhibit better performance at higher frequencies (140 Hz). Appropriate matching of driver materials and frequencies may help optimize wave field quality, thereby providing more reliable myocardial stiffness estimates.

Graphical Abstract

References

【1】
【1】
 
 
iRADIOLOGY
Pages 424-433

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Cheng Y, Wang J, Xu S, et al. Effect of Driver Material Properties and Excitation Frequencies on Quantitative Myocardial Stiffness Measurements in Magnetic Resonance Elastography. iRADIOLOGY, 2026, 4(5): 424-433. https://doi.org/10.1002/ird3.70106

5

Views

0

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 17 January 2026
Revised: 27 July 2026
Accepted: 31 August 2026
Published: 13 October 2026
© 2026 The Author(s). Tsinghua University Press.

This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.