AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
Home iLABMED Article
PDF (1.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Open Access

Dye‐based recombinase‐aided amplification assay with enhanced sensitivity and specificity

Zijin Zhao1,2Yanbo You3Shaowei Hua1,2Xinxin Shen1( )Lingjun Li3( )Xuejun Ma1 ( )
National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, NHC Key Laboratory of Medical Virology and Viral Diseases, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China 2Graduate School, Hebei North University, Zhangjiakou, Hebei, China
Graduate School, Hebei North University, Zhangjiakou, Hebei, China
State Key Laboratory of Antiviral Drugs, NMPA Key Laboratory for Research and Evaluation of Innovative Drug, Pingyuan Laboratory, School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, Henan, China
Show Author Information

Abstract

Background

Fluorescent recombinase‐aided amplification (RAA) assays are increasingly being used in the detection of a variety of pathogens and have the advantages of rapidity and simplicity and similar sensitivity and specificity, compared with real‐time PCR (qPCR) assays, but they require a complex probe design. To eliminate the addition of fluorescent probes for RAA, an EvaGreen dye‐based recombinase‐aided amplification (EvaGreen‐RAA) assay using self‐avoiding molecular recognition system (SAMRS) primers was developed.

Methods

The SAMRS primers effectively avoided the production of primer dimers, thus improving the detection sensitivity, while EvaGreen dye was used to quantitatively measure the amplified products in real time. Using Staphylococcus aureus (SA) and Listeria monocytogenes (LM) as examples, EvaGreen‐RAA with SAMRS primers was developed. As a reference and comparison, a traditional fluorescence probe RAA method and a RAA with SAMRS primers (SAMRS‐RAA) for detecting SA and LM were also investigated. Serial dilutions of recombinant plasmids were used to evaluate the sensitivity of the assays. Unenriched and enriched simulated milk samples were used to evaluate the limits of detection (LOD) of these methods. Using high‐resolution melting (HRM) was used to explore the sensitivity of the dual EvaGreen‐RAA assay.

Results

The sensitivity of the fluorescent RAA method for detecting SA and LM was 10 copies/μL using plasmids and the sensitivity of the SAMRS‐RAA and EvaGreen‐RAA for detecting SA and LM plasmids was 1 copies/μL. The LOD values of the EvaGreen‐RAA for SA and LM in unenriched simulated milk samples were 100 and 50 CFU/mL, respectively, and the LOD value for both SA and LM using enriched simulated milk samples was 10 CFU/mL. EvaGreen‐RAA had linear amplification in real time in the range of 1–105 copies/μL of the plasmids of SA and LM. The sensitivity of the dual EvaGreen‐RAA assay for SA and LM was estimated to be 102 CFU/mL.

Conclusion

A real‐time quantitative EvaGreen‐RAA method for detecting SA and LM was developed, which eliminates the need to design complex RAA probes. This dye‐based RAA with SARMS primers provides a new strategy for simplifying fluorescence probe RAA and allowing the detection of multiple pathogens, which has many potential applications.

Graphical Abstract

This article is based on an EvaGreen‐dye based recombinase aided amplification (EvaGreen‐RAA) assay using self‐avoiding molecular recognition system (SAMRS) primers for Staphylococcus aureus and Listeria monocytogenes. The SAMRS primers effectively avoid the production of primer dimers, thus improving the detection sensitivity while eliminating the addition of fluorescent probes for RAA. The EvaGreen‐RAA assays with SARMS primers provide a new strategy for simplifying fluorescence probe RAA and allowing the detection of multiple pathogens.

Electronic Supplementary Material

Download File(s)
ila-2-4-294_ESM.docx (248.7 KB)

References

【1】
【1】
 
 
iLABMED
Pages 294-306

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhao Z, You Y, Hua S, et al. Dye‐based recombinase‐aided amplification assay with enhanced sensitivity and specificity. iLABMED, 2024, 2(4): 294-306. https://doi.org/10.1002/ila2.51

975

Views

75

Downloads

1

Crossref

0

CSCD

Received: 23 April 2024
Accepted: 07 June 2024
Published: 14 July 2024
© 2024 The Author(s). Tsinghua University Press.

This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.