AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Self-Healable and Conductive Hydrogel Nanocomposite with High Environmental Stability for Electromagnetic-Interference-Free Electrocardiography Patches

Sang Yoon Park1,2, Se Jin Choi1,2, Jae Chan Kim3, Daniel J. Joe4( ), Han Eol Lee1,2,5 ( )
Department of JBNU-KIST Industry-Academia Convergence Research, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Korea
Division of Advanced Materials Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Korea
R&D Center, Bio Protech Inc, 151-3, Donghwagongdan-ro, Munmak-eup, Wonju-si, Gangwon-do 26365, Korea
Division of Biomedical Metrology, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Korea
Division of Electronics and Information Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Korea
Show Author Information

Abstract

Electrocardiogram (ECG) sensor is emerging as an essential medical device for diagnosing various cardiovascular diseases in modern people. Conventional ECG sensors have investigated by several researchers, but they still have significant issues of discomfort in wearing, easy swelling, poor electrical conductivity, and signal inaccuracy. Here, we demonstrate a hydrogel nanocomposite-based ECG sensor patches, monolithically integrated with a hydrogel-based biocompatible electrode and an electromagnetic interference (EMI) shielding layer in a single unit. The developed device with low impedance (20 kΩ) exhibited excellent mechanical properties including adhesion force (35.8 N m−1), multiple detachability (5 times), stretching/twisting stability and self-healing characteristic. The ECG sensor displayed superior long-term humidity stability for 30 days, showing superior biocompatibility. Finally, the ECG patch with high EMI shielding property monitored human vital signal and pulse rate changes in real-time.

Electronic Supplementary Material

Video
eem-8-5-e70039_ESM2.mp4
Download File(s)
eem-8-5-e70039_ESM1.docx (8.2 MB)

References

【1】
【1】
 
 
Energy & Environmental Materials

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Park SY, Choi SJ, Kim JC, et al. Self-Healable and Conductive Hydrogel Nanocomposite with High Environmental Stability for Electromagnetic-Interference-Free Electrocardiography Patches. Energy & Environmental Materials, 2025, 8(5). https://doi.org/10.1002/eem2.70039

709

Views

1

Downloads

29

Crossref

30

Web of Science

32

Scopus

0

CSCD

Received: 13 March 2025
Revised: 30 April 2025
Published: 02 May 2025
© 2025 The Author(s).

This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.