Wearable Multifunctional Health Monitoring Systems Enabled by Ultrafast Flash-Induced 3D Porous Graphene

Se Jin Choi1,2, Chan Hyeok Kim3, Jeong Hyeon Kim1,2, Kang Hyeon Kim2,4, Sang Yoon Park1,2, Yu Jin Ko2, Hosung Kang5,6, Young Bin Kim7, Yu Mi Woo8, Jae Young Seok9, Bongchul Kang10, Chang Kyu Jeong1,2, Kwi-Il Park11, Geon-Tae Hwang12, Jung Hwan Park8( ), Han Eol Lee1,2,3 ( )
Department of JBNU-KIST Industry-Academia Convergence Research, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Korea
Division of Advanced Materials Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Korea
Division of Electronics and Information Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, Korea
School of Mechanical System Engineering, Kumoh National Institute of Technology, 61 Daehak-ro, Gumi, Gyeongbuk 39177, Korea
Institute of Battery R&D, LG Energy Solution, 118, Munji-ro, Daejeon 34122, Korea
Department of Biological and Environmental Engineering, Cornell University, 111 Wing Dr, Ithaca, New York 14853, USA
Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-Ro, Yuseong-Gu, Daejeon 34141, Korea
Department of Mechanical Engineering (Department of Aeronautics, Mechanical and Electronic Convergence Engineering), Kumoh National Institute of Technology, 61 Daehak-Ro, Gumi, Gyeongbuk 39177, Korea
Department of Mechanical System Design Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Korea
School of Mechanical Engineering, Kookmin University, 77 Jeongneung-ro, Seongbuk-gu, Seoul 02707, Korea
Department of Materials Science and Metallurgical Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu 41566, Korea
Department of Materials Science and Engineering, Pukyong National University, 45 Yongso-ro, Nam-Gu. Busan, 48513, Korea
Show Author Information

Abstract

A wearable health monitoring system is a promising device for opening the era of the fourth industrial revolution due to increasing interest in health among modern people. Wearable health monitoring systems were demonstrated by several researchers, but still have critical issues of low performance, inefficient and complex fabrication processes. Here, we present the world’s first wearable multifunctional health monitoring system based on flash-induced porous graphene (FPG). FPG was efficiently synthesized via flash lamp, resulting in a large area in four milliseconds. Moreover, to demonstrate the sensing performance of FPG, a wearable multifunctional health monitoring system was fabricated onto a single substrate. A carbon nanotube-polydimethylsiloxane (CNT-PDMS) nanocomposite electrode was successfully formed on the uneven FPG surface using screen printing. The performance of the FPG-based wearable multifunctional health monitoring system was enhanced by the large surface area of the 3D-porous structure FPG. Finally, the FPG-based wearable multifunctional health monitoring system effectively detected motion, skin temperature, and sweat with a strain GF of 2564.38, a linear thermal response of 0.98 Ω ℃−1 under the skin temperature range, and a low ion detection limit of 10 μM.

Electronic Supplementary Material

Download File(s)
eem-8-4-e70005_ESM.docx (6.2 MB)

References

【1】
【1】
 
 
Energy & Environmental Materials

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Choi SJ, Kim CH, Kim JH, et al. Wearable Multifunctional Health Monitoring Systems Enabled by Ultrafast Flash-Induced 3D Porous Graphene. Energy & Environmental Materials, 2025, 8(4). https://doi.org/10.1002/eem2.70005

633

Views

3

Downloads

9

Crossref

8

Web of Science

8

Scopus

0

CSCD

Received: 24 January 2025
Revised: 05 February 2025
Published: 07 February 2025
© 2025 The Author(s).

This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.