AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Research Article | Open Access

Organic X-Ray Image Sensors Using a Medium Bandgap Polymer Donor with Low Dark Current

Jong-Woon Ha1,2 , Seung Hun Eom2, Bo Kyung Cha3, Seyeong Song4, Hyeong Ju Eun5, Jong H. Kim5, Jong Mok Park6, BongSoo Kim7, Byoungwook Park2, Seo-Jin Ko2, Sung Cheol Yoon2, Changjin Lee2, In Hwan Jung8 , Do-Hoon Hwang1( )
Department of Chemistry, Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
Division of Advanced Energy Materials Research Center, Korea Research Institute of Chemical Technology (KRICT), Daejeon 34114, Korea
Electro-Medical Device Research Center, Korea Electrotechnology Research Institute (KERI), Ansan 15588, Korea
Graduate School of Carbon Neutrality, School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea
Department of Molecular Science and Technology, Ajou University, Suwon 16449, Korea
Research Center for Advanced Specialty Chemicals, Korea Research Institute of Chemical Technology, Ulsan 44412, Korea
Department of Chemistry, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea
Department of Organic and Nano Engineering, Human-Tech Convergence Program, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul 04763, Korea
Show Author Information

Abstract

The development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations. However, this is quite challenging because of the heavy weight of the scintillator and silicon photodetectors. The weight and thickness of X-ray detectors can be reduced by replacing the silicon layer with an organic photodetectors. This study presents a novel bithienopyrroledione-based polymer donor that exhibits excellent photodetection properties even in a thick photoactive layer (~700 nm), owing to the symmetric backbone and highly soluble molecular structure of bithienopyrroledione. The ability of bithienopyrroledione-based polymer donor to strongly suppress the dark current density (Jd ~ 10−10 A cm−2) at a negative bias (−2.0 V) while maintaining high responsivity (R = 0.29 A W−1) even at a thickness of 700 nm results in a maximum shot-noise-limited specific detectivity of Dsh* = 2.18 × 1013 Jones in the organic photodetectors. Printed organic photodetectors are developed by slot-die coating for use in X-ray detectors, which exhibit Dsh* = 2.73 × 1012 Jones with clear rising (0.26 s) and falling (0.29 s) response times upon X-ray irradiation. Detection reliability is also proven by linear response of the X-ray detector, and the X-ray detection limit is 3 mA.

Electronic Supplementary Material

Download File(s)
eem-7-6-e12750_ESM.docx (4.9 MB)

References

【1】
【1】
 
 
Energy & Environmental Materials

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ha J-W, Eom SH, Cha BK, et al. Organic X-Ray Image Sensors Using a Medium Bandgap Polymer Donor with Low Dark Current. Energy & Environmental Materials, 2024, 7(6). https://doi.org/10.1002/eem2.12750

493

Views

7

Downloads

11

Crossref

10

Web of Science

12

Scopus

0

CSCD

Received: 10 September 2023
Revised: 25 January 2024
Published: 04 February 2024
© 2024 The Authors.

This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.