@article{Tang2026, 
author = {Weifeng Tang and Youzhi Zhao and Shuo Zhang and Yongshen Ou and Yongmin Zhang and Wenxiao Chu and Qiuwang Wang},
title = {The temperature control performance of deep-well fracturing equipment based on thermoelectric cooling technology},
year = {2026},
journal = {Journal of Northwest University (Natural Science Edition)},
volume = {56},
number = {5},
pages = {983-995},
keywords = {downhole environment, thermoelectric cooling, temperature control performance, maximum temperature difference, COP},
url = {https://www.sciopen.com/article/10.16152/j.cnki.xdxbzr.2026-05-003},
doi = {10.16152/j.cnki.xdxbzr.2026-05-003},
abstract = {The exploration and exploitation of deep-well resources such as oil, gas, and geothermal energy are crucial for achieving the green and efficient conversion and utilization of energy and resources. However, the extreme high temperatures (&gt;150 ℃) encountered downhole severely constrain the reliable operation of critical electronic components, including motors and power chips. Thermoelectric cooling, an active solid-state thermal control technology based on semiconductor direct energy conversion (electric-to-thermal), holds potential for thermal management in extreme environments due to the advantages such as compact structure and fast response. To investigate the performance limits and energy utilization efficiency of thermoelectric cooler(TEC) in deep-well high-temperature environments, this study systematically examined the temperature control characteristics of a TEC module under ambient temperatures ranging from 80 ℃ to 150 ℃ and a thermal load of 13.6 W, employing a combination of experimental measurements and numerical simulations. Experimental results demonstrate that under a 120 ℃ ambient temperature and 13.6 W thermal load, the TEC device can sustain a maximum temperature difference of 62.1 ℃ between its hot and cold ends, maintaining the cold-end surface temperature stably below 80 ℃. A reliable numerical prediction model was developed and validated. Simulation results revealed the dependence of the cold-end temperature on input current and demonstrated the independence of the maximum input current from the hot-end temperature. An approximate linear relationship between the maximum cooling capacity and the hot-end temperature was identified. Crucially for efficient energy utilization, the study confirmed the existence of an optimal operating current that minimizes the cold-end temperature, and this optimal current was found to be largely insensitive to the ambient temperature within the studied range. Furthermore, the analysis of the coefficient of performance (COP) indicated a trend where it initially increases with input current, reaches a peak, and then decreases. The magnitude of the COP increase was observed to be more significant at smaller temperature differences compared to larger ones. The findings suggest that enhancing hot-end heat dissipation and mitigating internal heat accumulation (due to the Joule effect) are effective strategies for improving the overall energy conversion performance of TECs, particularly under the large temperature differences characteristic of deep-well environments.}
}