@article{HU2022, 
author = {Tianfei HU and Li WANG},
title = {Ground source heat pump heating of embankments in cold regions to eliminate frost heave},
year = {2022},
journal = {Journal of Tsinghua University (Science and Technology)},
volume = {62},
number = {5},
pages = {871-880},
keywords = {embankment frost heave, artificial heating, heat pumps, heating temperature, freezing depth},
url = {https://www.sciopen.com/article/10.16511/j.cnki.qhdxxb.2022.21.007},
doi = {10.16511/j.cnki.qhdxxb.2022.21.007},
abstract = {A ground source heat pump system was designed for heating embankments to eliminate frost heave. Tests showed that the device can automatically output heating temperatures of 40, 50, or 60℃ with coefficients of performance greater than 3.0. The heating influenced a 0.76 m radius region on the 1st day, 1.64 m on the 5th day, and 2.30 m on the 10th day. A case study showed that the central freezing depth of an embankment was 0.89 m for standard conditions but was reduced to less than 0.2 m with artificial heating. The soil temperature rise and the heat diffusion both increased with increased heating temperature. Rapid thawing and emergency rescues during frost heave conditions require that the heat pumps have longitudinal spacings along the embankment of 2.0-4.0 m and heating capacities of 1.0-2.0 kW.}
}