@article{Pérez2023, 
author = {Sebastián Eustaquio Martín Pérez and Raúl Hernández García and Alberto Brito Lorenzo and Carlos Daniel Sabater Cruz and Mario Herrera Pérez and Fidel Rodríguez Hernández and Kristin Briem and Isidro Miguel Martín Pérez},
title = {Ultrasonographic Identification of Muscle Atrophy in Hamstring Muscles after Anterior Cruciate Ligament Repair among Soccer Players: A Case-control Study},
year = {2023},
journal = {Advanced Ultrasound in Diagnosis and Therapy},
volume = {7},
number = {4},
pages = {381-389},
keywords = {ACLR, Ultrasonography, Atrophy, Hamstring},
url = {https://www.sciopen.com/article/10.37015/AUDT.2023.230036},
doi = {10.37015/AUDT.2023.230036},
abstract = {ObjectivesTo measure the CSA of the HST musculature measured with ultrasonography in soccer players undergoing ACLR and compare limb differences with healthy controls.MethodsA case-control study was performed with patients after anterior cruciate ligament repair (ACLR) and healthy controls in which cross-sectional areas (CSA) obtained using a model TE7 ultrasound machine (MINDRAY ®, USA) in B mode (4.2 to 13 MHz) with a multifrequency linear array transducer (L12-4S). Three CSA images were taken of the semitendinosus muscle (ST) and the long head of the biceps femoris (BFlh), at a distance of 30% and 70% of the ischial tuberosity insertion. Mean differences between groups were analyzed using SPSS v.20 (IBM®, USA), and statistical analyses were performed using non-parametric techniques to determine differences between groups (Student's t-test) and Cohen's correlation coefficient to quantify effect size.Results14 ACLR operated 17 ± 5.4 months ago and 12 healthy controls (W = 6; M = 20M; 24.5 ± 3.92 years; BMI = 25.1 ± 2.32 kg/m2) were recruited. There were differences between groups in CSA-ST70 (Post-ACLR = 1.43 ± 1.029 cm2 vs Control 2.65 ± 0.664 cm2, T Student = -3.68, 95% CI [-Inf, -0.648], P &lt; 0. 001, ES = -1.418), but not in CSA-ST30 (Post-ACLR = 8.42 ± 1.596 cm2 vs Control 9.16 ± 0.945 cm2, T Student = -1.535; 95% CI [-Inf, -0.0793], P = 0. 068, ES = -0.5607), CSA-BFlh30 (Post-ACLR = 8.79 ± 1.47 cm2 vs Control 8.87 ± 2.312 cm2, T Student = -0.123; 95% CI [-Inf, 1.1049], P = 0.452, ES = -0. 049) or CSA-BFlh70 (Post-ACLR = 6.91 ± 1.011 cm2 vs Control 7.01 ± 1.453 cm2, T Student = -0.214; 95% CI [-Inf, 0.6795], P = 0.416, ES = -0.0783).ConclusionUltrasound measurement of the CSA can be an image marker to identify muscle weakness or atrophy that predicts functional loss early.}
}