AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Original Article | Open Access

Hydrogen underground storage efficiency in a heterogeneous sandstone reservoir

Petroleum Technology Department, University of Technology, Baghdad 10066, Iraq
Western Australia School of Mines: Minerals, Energy and Chemical Engineering, Discipline of Petroleum Engineering, Curtin University, Kensington 6151, Western Australia, Australia
School of Earth Sciences, Yunnan University, Kunming 650500, P. R. China
Key Laboratory of Deep-Earth Dynamics of Ministry of Natural Resources, Chinese Academy of Geological Sciences, Institute of Geology, Beijing 100037, P. R. China
Department of Earth Science and Engineering, Imperial College London, London SW7 2BP, UK
School of Engineering, Edith Cowan University, Joondalup 6027, Western Australia, Australia
Show Author Information

Abstract

Underground hydrogen storage has been recognized as a key technology for storing enormous amounts of hydrogen, thus aiding in the industrial-scale application of a hydrogen economy. However, underground hydrogen storage is only poorly understood, which leads to high project risk. This research thus examined the effect of caprock availability and hydrogen injection rate on hydrogen recovery factor and hydrogen leakage rate to address some fundamental questions related to underground hydrogen storage. A three dimensional heterogeneous reservoir model was developed, and the impact of caprock and hydrogen injected rate on hydrogen underground storage efficiency were analysed with the model. The results indicate that both caprock and injection rate have an important impact on hydrogen leakage, and the quantities of trapped and recovered hydrogen. It is concluded that higher injection rate increases H 2 leakage when caprocks are absent. In addition, lower injection rates and caprock availability increases the amount of recovered hydrogen. This work therefore provided fundamental information regarding underground hydrogen storage project assessment, and supports the decarbonisation of the energy supply chain.

References

【1】
【1】
 
 
Advances in Geo-Energy Research
Pages 437-443

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Mahdi DS, Al-Khdheeawi EA, Yuan Y, et al. Hydrogen underground storage efficiency in a heterogeneous sandstone reservoir. Advances in Geo-Energy Research, 2021, 5(4): 437-443. https://doi.org/10.46690/ager.2021.04.08

4001

Views

739

Downloads

114

Crossref

109

Web of Science

122

Scopus

Received: 06 November 2021
Revised: 18 November 2021
Accepted: 19 November 2021
Published: 21 November 2021
© The Author(s) 2021.

This article is distributed under the terms and conditions of the Creative Commons Attribution (CC BY-NC-ND) license, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.