AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (42.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Article | Open Access

Numerical and Experimental Study of Thermal Storage Energy in a Building with Various Pipeline Design under Floor—Case Study

Rafah H. Zaidan( ), Najim A. Jasim
Mechanical Department, Engineering College University of Baghdad, Baghdad, 10074, Iraq
Show Author Information

Abstract

This paper presents a comprehensive experimental and numerical investigation of radiant floor heating (RFH) systems integrated with phase change material (PCM)-based thermal energy storage (TES). The study compares two underfloor pipe configurations: double serpentine and spiral. It also looks at how well a paraffin wax PCM system works with compact heat exchanger-type TES units during winter in Iraq. Key performance indicators including discharge temperature, heat transfer rate, liquid fraction evolution, and temperature uniformity were assessed through in situ experimental measurements and ANSYS fluent simulations. Results demonstrate that the spiral design provides slightly more uniform temperature distribution on the tile surface at an inlet water temperature of 55°C, with an average difference of approximately 0.5%, the serpentine layout exhibits higher slab temperature distribution by about 0.66%. Notably, the serpentine configuration shows superior thermal homogeneity and heat distribution, with a 15.05% increase in heat gain at a 55°C inlet temperature compared to the spiral design. The performance gap between the two layouts narrows as the inlet temperature increases from 50°C in 5°C increments by approximately 4.1%, 3.7%, and 1.7%, respectively. Higher inlet temperatures also improve PCM discharging and charging rates, improving energy storage utilization. The findings provide significant design guidelines for sustainable heating systems for cold climates.

References

【1】
【1】
 
 
Frontiers in Heat and Mass Transfer
Pages 1595-1620

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zaidan RH, Jasim NA. Numerical and Experimental Study of Thermal Storage Energy in a Building with Various Pipeline Design under Floor—Case Study. Frontiers in Heat and Mass Transfer, 2025, 23(5): 1595-1620. https://doi.org/10.32604/fhmt.2025.068205

1106

Views

47

Downloads

0

Crossref

0

Web of Science

0

Scopus

Received: 23 May 2025
Accepted: 14 August 2025
Published: 31 October 2025
© The Author 2024.

This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.