Estimating the carbon emission reduction potential of using carbon-oriented demand response for data centers: A case study in China

Bojun Du1Hongyang Jia1Yaowang Li2( )Ershun Du3Ning Zhang1Dong Liang4
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
Sichuan Energy Internet Research Institute, Tsinghua University, Chengdu 610213, China
Laboratory of Low Carbon Energy, Tsinghua University, Beijing 100084, China
State Grid Jibei Electric Power Company Limited, Beijing 100054, China
Show Author Information

Abstract

The rapid advancement of artificial intelligence (AI) has significantly increased the computational load on data centers. AI-related computational activities consume considerable electricity and result in substantial carbon emissions. To mitigate these emissions, future data centers should be strategically planned and operated to fully utilize renewable energy resources while meeting growing computational demands. This paper aims to investigate how much carbon emission reduction can be achieved by using a carbon-oriented demand response to guide the optimal planning and operation of data centers. A carbon-oriented data center planning model is proposed that considers the carbon-oriented demand response of the AI load. In the planning model, future operation simulations comprehensively coordinate the temporal‒spatial flexibility of computational loads and the quality of service (QoS). An empirical study based on the proposed models is conducted on real-world data from China. The results from the empirical analysis show that newly constructed data centers are recommended to be built in Gansu Province, Ningxia Hui Autonomous Region, Sichuan Province, Inner Mongolia Autonomous Region, and Qinghai Province, accounting for 57% of the total national increase in server capacity. 33% of the computational load from Eastern China should be transferred to the West, which could reduce the overall load carbon emissions by 26%.

Electronic Supplementary Material

Download File(s)
54-64-SI_ESM.pdf (1 MB)

References

【1】
【1】
 
 
iEnergy
Pages 54-64

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Du B, Jia H, Li Y, et al. Estimating the carbon emission reduction potential of using carbon-oriented demand response for data centers: A case study in China. iEnergy, 2025, 4(1): 54-64. https://doi.org/10.23919/IEN.2025.0007

3441

Views

189

Downloads

8

Crossref

4

Web of Science

6

Scopus

Received: 04 December 2024
Revised: 07 January 2025
Accepted: 10 March 2025
Published: 24 March 2025
© The author(s) 2025.

This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).