AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.5 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Comparison of four different techniques for lenticule dissection in small incision lenticule extraction

Man-Li Liu, Jia-Bei Zhou, Quan Liu( ), Chong-De Long( )
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou 510060, Guangdong Province, China

Co-first Authors: Man-Li Liu and Jia-Bei Zhou

Show Author Information

Abstract

AIM

To compare the safety, efficacy, and technical demands of four lenticule‑dissection techniques—dry dissection, continuous curvilinear lenticulorrhexis (CCL), wet dissection, and Viscoat‑assisted dissection—in small incision lenticule extraction (SMILE), and to identify the method that minimizes tissue damage while preserving corneal clarity and early visual quality.

METHODS

Twenty‑eight eyes undergoing SMILE were assigned to four groups: dry dissection (n=10), CCL (n=5), wet dissection (n=10), and Viscoat‑assisted dissection (n=3). Surgical interfaces were evaluated with in vivo confocal microscopy and the anterior and posterior lenticule surfaces were examined by scanning electron microscopy. Two masked observers scored surface quality using four predefined criteria (surface relief, regularity of surface structure, proportion of irregular surface, and location of irregular area). Intraoperative dissection time, operator‑reported technical difficulty, and early postoperative corneal clarity/interface reaction were recorded.

RESULTS

Mean anterior surface scores were: dry 10.87±1.28; CCL 13.60±0.51; wet 13.67±0.48; Viscoat 4.22±0.44. Mean posterior surface scores were: dry 10.87±1.53; CCL 13.60±0.63; wet 14.10±0.48; Viscoat 4.33±0.50. Lenticules obtained via CCL and wet dissection showed significantly better surface quality than those from dry dissection and Viscoat‑assisted dissection (all P<0.01). Wet dissection produced surface quality comparable to CCL while being technically easier to perform; dissection times were similar between dry (48.8±3.58s) and wet (48.4±1.71s) techniques (P=0.123). Viscoat‑assisted cases demonstrated transient early postoperative corneal opacity that resolved as the viscoelastic was absorbed in 2wk; no significant early interface residue or lasting opacity was observed after wet dissection.

CONCLUSION

Wet dissection achieves lenticule surface quality comparable to CCL but with lower technical difficulty and without significant early postoperative adverse effects, making it a safe, effective, and easily adoptable option for lenticule separation in SMILE. Lenticule surface‑quality scoring provides a practical surrogate for assessing tissue damage across dissection methods.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 933-938

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Liu M-L, Zhou J-B, Liu Q, et al. Comparison of four different techniques for lenticule dissection in small incision lenticule extraction. International Journal of Ophthalmology, 2026, 19(5): 933-938. https://doi.org/10.18240/ijo.2026.05.13

526

Views

37

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 22 May 2025
Accepted: 16 September 2025
Published: 18 May 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).