AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Repeatability, reproducibility, and agreement regarding measurement of choroidal vascularity index between OCT and OCT angiography

Mu-Han ZhongJia-Li ZhangKe-Xin YuShu-Qi FanXue LiHao ChenJin-Hua Bao( )Ying-Ying Huang( )
National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China

Co-first Authors: Mu-Han Zhong and Jia-Li Zhang

Show Author Information

Abstract

AIM

To explore the repeatability, reproducibility, and agreement in the measurement of the choroidal vascularity index (CVI) for different swept-source optical coherence tomography (OCT) devices and between OCT and OCT angiography (OCTA) images.

METHODS

Two swept-source OCT imaging systems, VG200I and Topcon DRI OCT Triton, were used to capture OCT and OCTA images in triplicate. The first and third images were taken by one operator, and the second image was taken by another operator. The built-in software was used to calculate the CVI from the OCTA images (CVI-OCTA), and a custom-designed algorithm was used to calculate the CVI from the OCT images (CVI-OCT). Repeatability and reproducibility were assessed with the intraclass correlation coefficient (ICC), and agreement between devices and between OCT and OCTA were evaluated with Bland-Altman analysis.

RESULTS

Sixty-eight eyes from 35 adults (17 females) were included in the analysis. The average age of the participants was 23.6±2.3y, with an average spherical equivalent refraction of -3.08±2.47 D and an average AL of 25.21±1.20 mm. Both OCT devices demonstrated high repeatability and reproducibility in measuring the CVI-OCTA (all ICCs>0.894 across five choroidal regions) and CVI-OCT (all ICCs>0.838). Furthermore, the between-device agreement in measuring the CVI-OCT was good [mean difference (MD) ranging from -2.32% to -3.07%], but that in measuring the CVI-OCTA was poor (MD, 1.48% to -7.43%). Additionally, the between-imaging agreement (CVI-OCTA versus CVI-OCT) was poor for both devices (Triton, MD, 6.05% to 12.68%; VG200I, MD, 6.67% to 12.09%).

CONCLUSION

Both OCT devices and the two analytical methods demonstrate good stability. The inter-device consistency of CVI-OCT is good, while the inter-device consistency of CVI-OCTA and the consistency between the two analytical methods in the same device are both poor.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 498-508

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhong M-H, Zhang J-L, Yu K-X, et al. Repeatability, reproducibility, and agreement regarding measurement of choroidal vascularity index between OCT and OCT angiography. International Journal of Ophthalmology, 2026, 19(3): 498-508. https://doi.org/10.18240/ijo.2026.03.10

785

Views

30

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 26 July 2025
Accepted: 16 September 2025
Published: 18 March 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).