Clinical Research | Open Access

Intraocular lens tilt and decentration in congenital ectopia lentis: baseline characteristics and first-year report

Hui-Wen YeXin-Xin LiuZhen-Zhen LiuYi-Yuan MaXin-Yu ZhangDan-Ying Zheng( )Guang-Ming Jin( )
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Disease, Guangzhou 510060, Guangdong Province, China

Co-first Authors: Hui-Wen Ye and Xin-Xin Liu

Show Author Information

Abstract

AIM

To investigate the characteristics and associated factors of intraocular lens (IOL) tilt and decentration after transscleral suture-fixated IOL surgery in congenital ectopia lentis (CEL).

METHODS

CEL patients undergoing transscleral suture-fixated IOL surgery were divided into two groups based on implanted IOL type (three-piece IOL or one-piece IOL). The IOL tilt and decentration at 3-month and 1-year postoperative were measured. Multivariate regression analyses were performed to identify the associated factors of IOL tilt and decentration as well as longitudinal changes.

RESULTS

The 61 CEL patients (mean age 9.07±5.05y) in three-piece IOL (M/F: 14/7) group had a greater tilt than those with one-piece IOL (M/F: 28/12) group both at 3-month postoperative (horizontal: P=0.024; vertical: P=0.048) and 1-year postoperative (horizontal: P=0.011; vertical: P=0.001). Three-piece IOL group had a greater longitudinal change between 3-month postoperative to 1-year postoperative in IOL tilt (horizontal: P=0.028; vertical: P=0.026) and a greater longitudinal change in horizontal IOL decentration than one-piece IOL group (P<0.05). The longer axial length (AL) was associated with the longitudinal changes in IOL tilt (P=0.039), while the three-piece IOL was associated with the longitudinal changes in horizontal IOL decentration 1-year postoperatively (P=0.011).

CONCLUSION

IOL tilt is greater in the three-piece IOL group than that in the one-piece IOL group 1-year postoperatively. The three-piece IOL is associated with greater longitudinal changes of IOL decentration, while longer AL is associated with longitudinal changes of IOL tilt. For CEL patients, more stable IOL type should be selected and patients with longer AL warrant closer monitoring.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 468-474

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ye H-W, Liu X-X, Liu Z-Z, et al. Intraocular lens tilt and decentration in congenital ectopia lentis: baseline characteristics and first-year report. International Journal of Ophthalmology, 2026, 19(3): 468-474. https://doi.org/10.18240/ijo.2026.03.06

376

Views

26

Downloads

1

Crossref

1

Web of Science

1

Scopus

0

CSCD

Received: 07 February 2025
Accepted: 25 November 2025
Published: 18 March 2026
© 2026 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).