AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (929.8 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Clinical Research | Open Access

Maximizing extend visual outcomes with extend focus intraocular lens in eyes with axial length shorter than 24 mm

Yuan-Fei Zhu1,2, Li-Zhen Chen3, Tie-Ying Zhao2( ), Shao-Chong Zhang1( )
Shenzhen Eye Hospital, Jinan University, Shenzhen Eye Institute, Shenzhen 518000, Guangdong Province, China
Shenzhen Huaxia Eye Hospital, Huaxia Eye Hospital Group, Shenzhen 518000, Guangdong Province, China
C-MER (Shenzhen) Dennis Lam Eye Hospital, Shenzhen 518000, Guangdong Province, China

Co-first Authors: Yuan-Fei Zhu and Li-Zhen Chen

Show Author Information

Abstract

AIM

To evaluate the efficacy of the Tecnis® Symfony® ZXR00 lens in achieving optimal visual outcomes for cataract surgery patients with axial length (AL) shorter than 24 mm.

METHODS

A total of 21 subjects (37 eyes) were submitted to cataract surgery and implantation of Tecnis® Symfony® ZXR00 lens (Johnson & Johnson Vision) was assessed. Patients were examined at 5 m, 80 cm, and 40 cm for uncorrected distance visual acuity (UCDVA) and corrected distance visual acuity (CDVA), uncorrected intermediate (UCIVA), and uncorrected near visual acuity (UCNVA). Further, based on the optimal distance correction, the monocular defocusing curve in the range of +0.5 to -3.5 D was investigated. A simple patient-reported spectacle independence questionnaire (PRSIQ) was used to evaluate subjects’ subjective feelings about their dependence on glasses at various distances. Multiple linear regression was employed to examine the association amony intraocular lenses (IOLs) diopter, AL, corneal curvature, anterior chamber depth, mean manifest refractive spherical equivalent, pupil, pupil/scan, target refraction, and near vision (logMAR).

RESULTS

The study demonstrated enhanced UCNVA alongside comparable distant vision and UCIVA outcomes in eyes with AL shorter than 24 mm. Mean post-operative UCDVA significantly improved from preoperative levels 0.530±0.406 (P=0.000). Notably, 83.3% of eyes achieved 0.01 logMAR in UCNVA. Five unilateral cases with blended IOL implantation also showed satisfactory visual acuity and satisfaction. The 90.5% (19/21) achieved spectacle independence. The average score for self-reported spectacle-independence on the PRSIQ was 3.52 with a standard deviation of 0.98. The results of the regression analysis revealed that one predictor, the pupil/scan accounted for 27.6% of the variation in near vision [logMAR; F(1,35)=13.33, P<0.01].

CONCLUSION

The results affirm the effectiveness of the Tecnis® Symfony® ZXR00 lens in enhancing visual outcomes for cataract surgery patients with AL shorter than 24 mm. Additionally, the pupil/scan emerges as a critical factor influencing postoperative near vision.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 2073-2078

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Zhu Y-F, Chen L-Z, Zhao T-Y, et al. Maximizing extend visual outcomes with extend focus intraocular lens in eyes with axial length shorter than 24 mm. International Journal of Ophthalmology, 2025, 18(11): 2073-2078. https://doi.org/10.18240/ijo.2025.11.08

804

Views

43

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 06 July 2024
Accepted: 11 June 2025
Published: 18 November 2025
© 2025 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).