AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.8 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Intelligent Ophthalmology | Open Access

Evaluation of a novel deep learning based screening system for pathologic myopia

Pei-Fang Ren1Xu-Yuan Tang1Chen-Ying Yu1Li-Li Zhu1Wei-Hua Yang2( )Ye Shen1( )
Department of Ophthalmology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310003, Zhejiang Province, China
Shenzhen Eye Hospital, Jinan University, Shenzhen 518040, Guangdong Province, China
Show Author Information

Abstract

AIM

To evaluate the clinical application value of the artificial intelligence assisted pathologic myopia (PM-AI) diagnosis model based on deep learning.

METHODS

A total of 1156 readable color fundus photographs were collected and annotated based on the diagnostic criteria of Meta-pathologic myopia (PM) (2015). The PM-AI system and four eye doctors (retinal specialists 1 and 2, and ophthalmologists 1 and 2) independently evaluated the color fundus photographs to determine whether they were indicative of PM or not and the presence of myopic choroidal neovascularization (mCNV). The performance of identification for PM and mCNV by the PM-AI system and the eye doctors was compared and evaluated via the relevant statistical analysis.

RESULTS

For PM identification, the sensitivity of the PM-AI system was 98.17%, which was comparable to specialist 1 (P=0.307), but was higher than specialist 2 and ophthalmologists 1 and 2 (P<0.001). The specificity of the PM-AI system was 93.06%, which was lower than specialists 1 and 2, but was higher than ophthalmologists 1 and 2. The PM-AI system showed the Kappa value of 0.904, while the Kappa values of specialists 1, 2 and ophthalmologists 1, 2 were 0.968, 0.916, 0.772 and 0.730, respectively. For mCNV identification, the AI system showed the sensitivity of 84.06%, which was comparable to specialists 1, 2 and ophthalmologist 2 (P>0.05), and was higher than ophthalmologist 1. The specificity of the PM-AI system was 95.31%, which was lower than specialists 1 and 2, but higher than ophthalmologists 1 and 2. The PM-AI system gave the Kappa value of 0.624, while the Kappa values of specialists 1, 2 and ophthalmologists 1 and 2 were 0.864, 0.732, 0.304 and 0.238, respectively.

CONCLUSION

In comparison to the senior ophthalmologists, the PM-AI system based on deep learning exhibits excellent performance in PM and mCNV identification. The effectiveness of PM-AI system is an auxiliary diagnosis tool for clinical screening of PM and mCNV.

References

【1】
【1】
 
 
International Journal of Ophthalmology
Pages 1417-1423

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Ren P-F, Tang X-Y, Yu C-Y, et al. Evaluation of a novel deep learning based screening system for pathologic myopia. International Journal of Ophthalmology, 2023, 16(9): 1417-1423. https://doi.org/10.18240/ijo.2023.09.07

495

Views

31

Downloads

7

Crossref

8

Web of Science

8

Scopus

0

CSCD

Received: 04 April 2023
Accepted: 10 May 2023
Published: 18 September 2023
© 2023 International Journal of Ophthalmology Press

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).