Voltage Support Capacity Improvement for Wind Farms with Reactive Power Substitution Control

Yuegong Li1, Guorong Zhu1,2, Jianghua Lu3, Hua Geng4( )
School of Automation, Wuhan University of Technology, Wuhan 430070, China
State Key Laboratory of Maritime Technology and Safety, Wuhan University of Technology, Wuhan 430063, China
College of Information Science and Engineering, Wuhan University of Science and Technology, Wuhan 430081, China
Department of Automation, Tsinghua University, Beijing 100084, China
Show Author Information

Abstract

Generally, voltage support at the point of common coupling (PCC) of a wind farm is achieved through centralized static var generators (SVGs). Since the reactive power requirements occupy their capacity in a steady state, the reactive power support capacity of the SVG is limited during high voltage ride through (HVRT) or low voltage ride through (LVRT). While wind turbines can provide voltage support in accordance with the grid code, their responses are usually delayed due to communication and transmission lags. To enhance the dynamic performance of wind farms during fault ride-through, a reactive power substitution (RPS) control strategy is proposed in this paper. In a steady state, this RPS control method preferentially utilizes the remaining capacity of wind turbines to substitute for the output of the SVG. Considering differences in terminal voltage characteristics and operating conditions, this RPS control method employs a particle swarm optimization (PSO) algorithm to ensure that wind turbines can provide their optimal reactive power support capacity. When the grid voltage swells or drops, the SVG has a sufficient reactive power reserve to support the grid quickly. This paper utilizes a regional power grid incorporating two wind farms connected to different buses as a case study to validate this RPS control strategy.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 999-1017

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li Y, Zhu G, Lu J, et al. Voltage Support Capacity Improvement for Wind Farms with Reactive Power Substitution Control. CSEE Journal of Power and Energy Systems, 2025, 11(3): 999-1017. https://doi.org/10.17775/CSEEJPES.2024.07190

878

Views

87

Downloads

8

Crossref

12

Web of Science

15

Scopus

0

CSCD

Received: 23 September 2024
Revised: 19 November 2024
Accepted: 23 December 2024
Published: 16 May 2025
© 2024 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).