AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (761.3 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Converters’ Loading Balance and Stability Verification for Doubly-fed Induction Generators

School of Electrical Engineering and Automation, Hefei University of Technology, and Anhui Province Key Laboratory of Renewable Energy Utilization and Energy Saving, Hefei 230009, China
Show Author Information

Abstract

Back-to-back converters are the main components of a doubly-fed induction generator (DFIG). If the loadings of the rotor-side converter (RSC) and the grid-side converter (GSC) are balanced, the capacity and the cost of the DFIG will be reduced. This paper balances the converters' loadings by adjusting reactive power of the GSC ( Q g ∗ ). The steady-state constraints of the DFIG are solved to quantify the imbalance degree. A sensitivity model of the unbalanced loading with respect to Q g ∗ is proposed to balance the loadings. To verify if loading adjustment reduces the stability of the DFIG, the eigen–sensitivity models, with respect to Q g ∗ and stator voltage, are newly proposed with the power flow Jacobian matrix. Numerical results verify the accuracy and efficiency of the proposed model. The loadings of the converters are balanced with a few adjustments. Loading balance has little negative impact on the stability of the DFIG.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1131-1140

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li S. Converters’ Loading Balance and Stability Verification for Doubly-fed Induction Generators. CSEE Journal of Power and Energy Systems, 2025, 11(3): 1131-1140. https://doi.org/10.17775/CSEEJPES.2021.01260

618

Views

56

Downloads

3

Crossref

4

Web of Science

4

Scopus

0

CSCD

Received: 18 February 2021
Revised: 22 March 2021
Accepted: 17 March 2021
Published: 05 January 2022
© 2021 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).