AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Self-correction Sensor for Measuring Medium DC Voltage Based on Resistance Voltage Divider

Xiaojun Tang1, Pan Pan1, Feng Zhang1, Ling Yan1, Yangyu Lyu1( ), Yi Wu2, Mingzhe Rong2, Berihun Gebreyohannes Teklu1
Department of Measurement & Control, School of Electrical Engineering, Xi’an Jiaotong University. Xi’an 710000, China
State Key Laboratory of Electrical Insulation & Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University. Xi’an 710000, China
Show Author Information

Abstract

With the rapid development of the direct current (DC) distribution network, DC voltage measurement technology is increasingly important to ensure safe operation in the distribution network. The measurement accuracy of the traditional sensor based on resistance dividers decreases over time because the resistors age due to temperature and electromagnetic radiation. To address this problem, a novel type of medium-voltage DC voltage sensor with self-correction ability is presented in this paper. A resistor with large R H is connected in series with R K and R G , i.e. two precise resistors with low resistance, to transform the measured medium voltage into low voltage. Among these three resistors in the divider, R H connects with the measured medium DC line, while R G connects with the ground. An electronic switch, K, is paralleled with R K , the precise resistor at the middle position. Generally, the state of the electronic switch is off, and the current flows through R K . Medium DC voltage can be measured according to the voltage on R G with the divider ratio. When the sensor needs self-correction, the electronic switch will be controlled by FPGA (Field Programmable Gate Array) to turn it off and on; therefore, two values of low voltage can be obtained using time-sharing sampling. Two equations can be built according to the divider principle, and R H in the divider can be evaluated by solving the equations. As a result, the measurement error caused by the change in R H can be avoided. Finally, the medium-voltage DC sensor developed in this paper has been tested at the Institute of High Voltage, Wuhan, China. The experimental results show that the sensor can perform self-correction without manual operation, and the sensor’s accuracy can reach 0.12%. Sensors with a self-calibration function can realize long-term high-precision measurement without manual maintenance, showing a good application prospect.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1165-1173

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Tang X, Pan P, Zhang F, et al. Self-correction Sensor for Measuring Medium DC Voltage Based on Resistance Voltage Divider. CSEE Journal of Power and Energy Systems, 2025, 11(3): 1165-1173. https://doi.org/10.17775/CSEEJPES.2021.00790

1285

Views

121

Downloads

2

Crossref

4

Web of Science

2

Scopus

0

CSCD

Received: 31 January 2021
Revised: 19 April 2021
Accepted: 09 July 2021
Published: 06 May 2022
© 2021 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).