AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Regular Paper | Open Access

Effect of Multiple Models of Closed-loop Transfer Functions on Inter-harmonic Oscillation Characteristics of Grid-connected PMSG

Jingyi Li1,2Jianjun Yang1 ( )Xiaorong Xie2Haozhi Li2Ke WangZhaohui Shi
Key Laboratory of Far-shore Wind Power Technology of Zhejiang Province, Huadong Engineering Corporation Limited, Power China, Hangzhou 310014, China
State Key Lab of Control and Simulation of Power Systems and Generation Equipment (Dept. of Electrical Engineering, Tsinghua University), Beijing 100084, China
Show Author Information

Abstract

Establishing a suitable closed-loop transfer function model for the grid-connected PMSG system is the key basis in performing inter-harmonic characteristics analysis. Multiple closed-loop transfer functions can be constructed when different components of the converter controller are taken into account. However, the effect of different components of the converter controller on inter-harmonic stability analysis is not clear. In this paper, the complete transfer function, considering different loops, is first given. Based on the complete closed-loop transfer function, the DC-link, PLL and voltage forward-feed are removed step by step to derive different closed-loop transfer functions. The inter-harmonic related poles of different closed-loop transfer functions are further calculated to analyze the effect of closed-loop transfer functions on inter-harmonic characteristics analysis. Finally, by performing time domain simulation, the correctness of the theoretical analysis results is verified. The results show that under the conditions of a weak AC system, each loop of the converter control system will reduce the stability of the inter-harmonic in the sub-synchronous frequency range and influence the inter-harmonic oscillation frequency. The transfer function needs to consider the influence of each loop to accurately calculate the inter-harmonic stability of the system.

References

【1】
【1】
 
 
CSEE Journal of Power and Energy Systems
Pages 1955-1964

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li J, Yang J, Xie X, et al. Effect of Multiple Models of Closed-loop Transfer Functions on Inter-harmonic Oscillation Characteristics of Grid-connected PMSG. CSEE Journal of Power and Energy Systems, 2024, 10(5): 1955-1964. https://doi.org/10.17775/CSEEJPES.2020.03920

545

Views

35

Downloads

2

Crossref

9

Web of Science

10

Scopus

1

CSCD

Received: 09 August 2020
Revised: 15 December 2020
Accepted: 26 February 2021
Published: 30 December 2021
© 2020 CSEE.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).