AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (12.1 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese

Traceable Flue Gas Flow Rate Measurement Method for Large-Diameter Stacks of Thermal Power Plant

Zhimin LU1( )Zili XIE1Weiye LU2Xiaoxuan CHEN2Yongru HUANG1Zeming LIU1Xuejun TIAN1Shunchun YAO1
School of Electric Power, South China University of Technology, Guangzhou 510640, Guangdong, China
Guangdong Institute of Special Equipment Inspection and Research Shunde Branch, Foshan 528300, Guangdong, China
Show Author Information

Abstract

The tracer gas dilution method can address the issue of significant measurement errors in flue gas flow caused by the complex flow field in large-diameter stacks of power plants. The method is traceable and operates on a measurement principle different from the conventional velocity-area method, making it a promising candidate for on-site calibration of flow measurements. To this end, this paper employs numerical simulation to analyze the feasibility and accuracy of the tracer gas dilution method for measuring flue gas flow in power plant stacks. On this basis, it studies the influence of the tracer gas dilution ratio and injection cross-section on measurement results. In addition, different tracer gas sampling schemes were designed to evaluate the stability of the measurements. The results demonstrate that, at a height of approximately 9D (where D is the stack diameter), the tracer gas achieves full mixing with the flue gas; both excessively high and low tracer gas dilution ratios can negatively affect the mixing efficiency; injecting the tracer gas at the flue section can effectively reduce flow measurement errors. Under 80% load rate, when the tracer gas is injected into the stack, the measurement errors vary considerably across different sampling schemes. However, the three-point sampling method demonstrates a stable and accurate performance, with measurement errors of only -3.59%, -0.69%, and -1.05% at the 3D, 8D, and 12D cross-sections, respectively. When the tracer gas is injected into the horizontal flue, the flow measurement errors for all sampling schemes remain within ±10%. Specifically, with three-point sampling, the errors at the 3D, 8D, and 12D cross-sections are 0.98%, -0.52%, and 0.21%, respectively—all within ±1%. These results demonstrate the feasibility and accuracy of the tracer gas dilution method for flue gas flow measurement in large-diameter stacks.

CLC number: TM621; TK31 Article ID: 1000-565X(2025)09-0138-11

References

【1】
【1】
 
 
Journal of South China University of Technology (Natural Science Edition)
Pages 138-148

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LU Z, XIE Z, LU W, et al. Traceable Flue Gas Flow Rate Measurement Method for Large-Diameter Stacks of Thermal Power Plant. Journal of South China University of Technology (Natural Science Edition), 2025, 53(9): 138-148. https://doi.org/10.12141/j.issn.1000-565X.240571

91

Views

1

Downloads

0

Crossref

0

Web of Science

0

Scopus

0

CSCD

Received: 05 December 2024
Published: 25 September 2025
© Journal of South China University of Technology (Natural Science Edition)