AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (2.3 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Prevention and Treatment Practice | Publishing Language: Chinese | Open Access

Application of a metal occlusal surface and split framework in the treatment of a patient with mandibular distal extension absence and insufficient occlusogingival distance

Jingting LUO1Yumin WANG2Guanyang SUN3Tian QIN4Guofeng WU5( )Ruikai BA6( )
9th Teams, Third Brigade, College of Basic Medicine, the Fourth Military Medical University, Xi'an 710032, China
12nd Teams, Third Brigade, College of Basic Medicine, the Fourth Military Medical University, Xi'an 710032, China
Department of Stomatology, the 83rd Affiliated Hospital of Xinxiang Medical College, Xinxiang 453000, China
Department of Prosthodontics, Jinan Stomatological Hospital, Jinan 250000, China
Department of Prosthodontics, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing 210008, China
State Key Laboratory of Military Stomatology, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University, Xi’an 710032, China
Show Author Information

Abstract

Objective

To investigate the effect of a metal occlusal surface and stress interruption design on minimally invasive prosthodontics for patients with distal extension absence and insufficient occlusal gingival distance.

Methods

We retrospectively studied the case of minimally invasive prosthodontic (Vitallium 2000) combined with a metal occlusal surface for distal extension absence in a patient with insufficient occlusal gingival distance; the stress breaking design and pressure impression technology are examined, and relevant articles are reviewd.

Results

The design effectively solves the problems of insufficient occlusal gingival distance, large occlusal force and easy denture fracture. Reviewing the relevant literature, stress interruption design can effectively protect abutment teeth, but the behavior of stress interruption design and stress conduction phenomena in the mouths of patients has not been reported. The T-scan test results of this study showed that before and after wearing the denture, the occlusal force distribution ratio of the patient changed from 77.5% on the left and 22.5% on the right to 61.3% on the left and 38.7% on the right. The occlusal force distribution ratio of the right dentition to the total occlusal force increased by 16.2%, and the occlusal force became better distributed. Further analysis showed that the occlusal forces on the left and right sides were nearly the same in the initial occlusion stage. As the occlusal force was further increased, the proportion of the occlusal force on the right side decreased in the middle of the occlusion stage and further decreased in the final occlusion stage until it reached a dynamic balance. The above T-scan test and literature review results suggest that this dynamic balance phenomenon of bite force is related to the stress interruption design and the stress conduction effect of the split framework.

Conclusion

The composite of stress interruption design and metal occlusal surface allows for minimally invasive prosthodontics for the treatment of distal extension absence in patients with insufficient occlusal gingival distance.

CLC number: R78 Document code: A Article ID: 2096-1456(2022)12-0871-07

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 871-877

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LUO J, WANG Y, SUN G, et al. Application of a metal occlusal surface and split framework in the treatment of a patient with mandibular distal extension absence and insufficient occlusogingival distance. Journal of Prevention and Treatment for Stomatological Diseases, 2022, 30(12): 871-877. https://doi.org/10.12016/j.issn.2096-1456.2022.12.006

95

Views

0

Downloads

0

Crossref

0

Scopus

Received: 26 April 2022
Revised: 06 July 2022
Published: 20 December 2022
© 2022 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases