AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.6 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Basic Study | Publishing Language: Chinese | Open Access

Effects of the different materials and thicknesses on endocrown stress distribution

Jie LIN1Zhenxiang LIN2Zhiqiang ZHENG1( )
Department of VIP Dental Service, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350002, China
Department of Stomatology, Hospital of Fujian Provincial Authorities, Fuzhou 350003, China
Show Author Information

Abstract

Objective

To analyze the effects of different restorations and the thickness of the occlusal space on the stress distribution of endodontically treated molars with endocrowns.

Methods

The finite element model of the restoration of the first mandibular molar was created, and four different endocrown materials were used including two resin based ceramics (Lava Ultimate, Vita Enamic), one lithium disilicate ceramic (IPS e.max CAD) and one zirconia ceramics (Cercon), and four kinds of surface space thickness were designed: 1 mm, 2 mm, 3 mm and 4 mm. A total of 600 N was loaded to simulate the maximum bite force in the vertical and inclined directions, and the finite element software ANSYS 10.0 was used to analyze the stress distribution.

Results

The vertical loading analysis showed that the crown stress of the 1 mm-Cercon group was the highest at 211.30 MPa, and that of the 4 mm-Lava Ultimate group was the lowest at 11.56 MPa; the highest dentin stress was 38.84 MPa in the 3 mm-Lava Ultimate group, and the lowest was 11.68 MPa in 1 mm-Cercon group. The stress in the periodontal ligament and alveolar bone had little change. The inclined loading analysis showed that the crown stress of the 1 mm-Cercon group was the highest at 78.73 MPa and that of the 1 mm-Lava Ultimate group was the lowest at 35.51 MPa; the highest dentin stress was 41.63 MPa in the 1 mm-Cercon cervical group, and the lowest was 10.81 MPa in the 4 mm-Cercon coronal group. The stress concentration of cement and cervical dentin under inclined loading was higher than that under vertical loading.

Conclusion

The results of finite element analysis show that the elastic modulus of the endocrown increases, the stress of the crown restoration shows an upward trend, and the stress in the tooth shows a downward trend. With increasing crown thickness, the stress of the crown prosthesis decreased.

CLC number: R78 Document code: A Article ID: 2096-1456(2021)11-0740-06

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 740-745

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LIN J, LIN Z, ZHENG Z. Effects of the different materials and thicknesses on endocrown stress distribution. Journal of Prevention and Treatment for Stomatological Diseases, 2021, 29(11): 740-745. https://doi.org/10.12016/j.issn.2096-1456.2021.11.003

92

Views

0

Downloads

0

Crossref

0

Scopus

Received: 26 March 2021
Revised: 23 April 2021
Published: 20 November 2021
© 2021 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases