Publishing Language: Chinese | Open Access

Clinical application of laser selective melting titanium alloy for removable partial denture frameworks

Wen ZHANG1Wenqiang XIE2Meihua ZHENG2( )Xiangbo KONG2
Department of Stomatology, the Second Hospital of Traditional Chinese Medicine of Guangdong Province, Guangzhou 510095, China
Department of Stomatology, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou 510120, China
Show Author Information

Abstract

Objective

To investigate the effect of denture stomatitis of selective laser melting (SLM) titanium alloy for removable partial denture frameworks.

Methods

Twenty patients with dentition defects in our hospital were divided into two groups according to the different methods of creating a removable partial denture framework: the SLM group and casting group. The success rate, placement rate, masticatory efficiency and incidence of denture stomatitis were compared. Experimental data were analyzed with SPSS20.0.

Results

The success rate of the SLM framework group was 100.00%, which was higher than that of the casting group (90.00%) (P < 0.01). The rate of framework placement in the SLM group was slightly lower than that in the casting group (P < 0.05). The masticatory efficiency of the SLM group was higher than that of the casting group (0.783 ± 0.030 vs. 0.699 ± 0.037, P < 0.001). The incidence of denture stomatitis (10.00%) in the SLM group was significantly lower than that in the casting group (30.00%) (P < 0.001).

Conclusion

SLM is superior to the traditional casting method in mastication efficiency and reducing the incidence of denture stomatitis. This method can meet the clinical requirements, but the accuracy of the long-term stent needs to be improved.

CLC number: R78 Document code: A Article ID: 2096-1456(2020)04-0231-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 231-235

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG W, XIE W, ZHENG M, et al. Clinical application of laser selective melting titanium alloy for removable partial denture frameworks. Journal of Prevention and Treatment for Stomatological Diseases, 2020, 28(4): 231-235. https://doi.org/10.12016/j.issn.2096-1456.2020.04.005

89

Views

0

Downloads

0

Crossref

0

Scopus

Received: 25 June 2018
Revised: 02 September 2019
Published: 20 April 2020
© 2020 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases