AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.2 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Prevention and Treatment Practice | Publishing Language: Chinese | Open Access

Comparison of the formation ability of two types of machine-made nickel-titanium instruments in simulated curved root canals

Tingting LIWei JIANGYueping PAN( )
Department of Endodontics, Shanghai Ninth People’ Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai 200011, China
Show Author Information

Abstract

Objective

To compare ProTaper Universal (PU) and M3-L instruments in preparing curved root canals and to provide a reference for clinical applications.

Methods

Twenty resin-simulated curved single root canals were randomly divided into two groups. Root canal preparation was performed with a PU nickel-titanium file or an M3-L nickel-titanium file. Root canal preparation time, root canal length before and after preparation and root canal deviation were recorded.

Results

In the M3-L group, the displacement measured at the 4th to 7th sites was less than that in the PU group (P < 0.05), but there was no significant difference between the other two groups (P > 0.05); The length of the root canal before and after root canal preparation in the M3-L group was (14.90 ± 1.92) mm and (14.57 ± 1.13) mm, respectively, and the difference between the two groups was not statistically significant (t=3.18, P=0.058). The root canal length before and after root canal preparation in the PU group was (14.53 ± 1.53) mm and (14.28 ± 1.39) mm, respectively. The difference between the two groups was not statistically significant (t=2.12, P=0.124); The average preparation time of the M3-L group [(110.15 ± 10.43) s] was less than that in the PU group [(330.48 ± 12.62) s] (P < 0.05).

Conclusion

The M3-L nickel-titanium file has better central positioning ability and is less time-consuming than the PU nickel-titanium file in root canal bending preparation.

CLC number: R781.05 Document code: A Article ID: 2096-1456(2019)04-0246-04

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 246-249

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LI T, JIANG W, PAN Y. Comparison of the formation ability of two types of machine-made nickel-titanium instruments in simulated curved root canals. Journal of Prevention and Treatment for Stomatological Diseases, 2019, 27(4): 246-249. https://doi.org/10.12016/j.issn.2096-1456.2019.04.008

78

Views

0

Downloads

0

Crossref

0

Scopus

Received: 30 October 2018
Revised: 15 November 2018
Published: 20 April 2019
© 2019 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases