The effects of two different patterns on the precision of zirconia all-ceramic crowns

Juan ZHANGDongjian LIJie JIANGYan SITUShuangshuang ZOUXingtao WEN( )
Department of Prosthodontics, Liwan District Stomatological Hospital of Guangzhou, Guangdong 510145, China
Show Author Information

Abstract

Objective

The objective of this study was to compare the early clinical effects of zirconia all-ceramic crowns using two different impression methods. Zirconia ceramic crowns were produced using digital models based on either a silicone rubber impression perfusion model in vitro or a 3D mouth scanner.

Methods

A total of 50 patients with a planned restoration of the first permanent molar with zirconia all-ceramic crowns after root canal therapy were selected and randomly divided into two groups: a digital impression by intraoral 3D scanning group and a digital impression by extraoral scanning after silicone rubber impression group. Zirconia all-ceramic crowns were created by CAD/CAM in both groups. Marginal adaptation, proximal contact, and occlusal contact were compared between groups.

Results

There was no significant difference between the two groups in marginal adaptation (P > 0.05). For proximal contact and occlusal contact, no significant differences regarding the number of cases for the criteria of level A and level B were found between two groups (P > 0.05), while the misfit value in level B was smaller in the first group than in the second group (P < 0.05).

Conclusion

Zirconia all-ceramic crowns with intraoral 3D scanning show excellent early clinical performance.

CLC number: R783.1 Document code: A Article ID: 2096-1456(2018)04-0245-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 245-249

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
ZHANG J, LI D, JIANG J, et al. The effects of two different patterns on the precision of zirconia all-ceramic crowns. Journal of Prevention and Treatment for Stomatological Diseases, 2018, 26(4): 245-249. https://doi.org/10.12016/j.issn.2096-1456.2018.04.009

88

Views

0

Downloads

0

Crossref

0

Scopus

Received: 18 May 2017
Revised: 10 July 2017
Published: 20 April 2018
© 2018 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases