AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (1.9 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

A retrospective study on the clinical outcomes of all-ceramic crowns restoration fabricated by oral digital impression

Jie JIANG( )Yan SITUJuan ZHANGDongjian LIBolin Ren
Stomatology Hospital of Liwan District of Guangzhou, Guangzhou 510000, China
Show Author Information

Abstract

Objective

To evaluate the clinical outcomes of all-ceramic crowns whose oral digital impressions were scanned by 3Shape Trios.

Methods

All the impressions were scanned by Trios and all the crowns were fabricated according to the standard procedure. The restoration quality were evaluated using modified United States Public Health Service (USPHS) criteria one year after treatment. Restoration integrity、marginal adaptation、enamel wear、color satisfaction and gingival index (GI) of the prostheses were evaluated according to the modified USPHS criteria.

Results

The clinical 1 year survival rate of 92 porcelain crowns fabricated by 3-shape Trios digital impression and made by CAD/CAM was 100%. The scored A rates of restoration integrity、marginal adaptation、enamel wear、secondary caries、color satisfaction and gingival index of the prostheses were 100%、91.3%、98%、95.6%、96.7% and 94.7% after 1 year, respectively.

Conclusion

The clinical outcomes of all-ceramic crowns whose oral digital impressions were scanned by 3Shape Trios and whose crowns were made by CAD-CAM are satisfying.

CLC number: R783.4 Document code: A Article ID: 2096-1456(2018)01-0038-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 38-42

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
JIANG J, SITU Y, ZHANG J, et al. A retrospective study on the clinical outcomes of all-ceramic crowns restoration fabricated by oral digital impression. Journal of Prevention and Treatment for Stomatological Diseases, 2018, 26(1): 38-42. https://doi.org/10.12016/j.issn.2096-1456.2018.01.007

104

Views

0

Downloads

0

Crossref

0

Scopus

Received: 25 June 2017
Revised: 03 July 2017
Published: 20 January 2018
© 2018 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases