AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (982.6 KB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Basic Study | Publishing Language: Chinese | Open Access

Effect of different treatment methods of polymeric porcelain surface on its adhesion to metal brackets

Li JI1Zhinong ZHU2Wenwei LIAN1( )Dongfang LI1( )
Department of Prothodontics, The Affiliated Stomatological Hospital of Nanchang University, Nanchang 330006, China
Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Nanchang University; The Key Laboratory of Oral Biomedicine, Nanchang 330006, China
Show Author Information

Abstract

Objective

To analyze and discuss the effect of 4 different surface treatment methods on the bonding effect between polymerization porcelain and metal bracket s.

Methods

45 polymer-ceramics specimens were made and 40 of them were selected and randomly divided into 5 groups according to different surface treatment methods. A group: surface without special treatment. B group: 9.6% hydrofluoric acid gel combine with bonding agent, C group: 9.6% hydrofluoric acid gel combine with silane, D group: 35% phosphoric acid gel combine with bonding agent, E group: 35% phosphoric acid gel combine with silane. All specimens were stored in water for 24 hours at 37 ℃ after bonding 10 min utes and then cycled 500 cycles (5 ℃ to 55 ℃). To measure the shear bonding strength and record the damage cases and the adhesive remnant index.

Results

The shear strength values were: 3.24 in the control group, 7.24 MPa in the hydrofluoric acid etching treatment group. 10.78 MPa in the hydrofluoric acid gel combined with silane group. 4.17 MPa in the phosphoric acid-only group, 6.84 MPa in the phosphoric acid gel combined with silane group. The results of each group were statistically different from those of the other four groups (P < 0.001). The rate of breakage after the removal of brackets of the hydrofluoric acid gel combined with silane group is higher than the others.

Conclusion

As to the high shear bonding strength and low rate of breakage after the removal of brackets, we recommend 35% phosphoric acid etching combining with silane coupling agent in clinical.

CLC number: R783.5 Document code: A Article ID: 2096-1456(2017)12-0779-05

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 779-783

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
JI L, ZHU Z, LIAN W, et al. Effect of different treatment methods of polymeric porcelain surface on its adhesion to metal brackets. Journal of Prevention and Treatment for Stomatological Diseases, 2017, 25(12): 779-783. https://doi.org/10.12016/j.issn.2096-1456.2017.12.006

86

Views

0

Downloads

0

Crossref

0

Scopus

Received: 21 February 2017
Revised: 23 April 2017
Published: 20 December 2017
© 2017 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases