AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (4.4 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Publishing Language: Chinese | Open Access

The accuracy analysis of fully-guided mucosa-supported template based computer-assisted implant surgery

Lili LUAN1Huijuan XIAO1Hui LIU2Xiaopeng HAN3Hui YU1Zhonghao LIU1( )
Dental Implant Center, Yantai Stomatology Hospital, Yantai 264001, China
Chinese Stomatological Association, Beijing 100081, China
Department of Prosthodontics, Yantai Stomatology Hospital, Yantai 264001, China
Show Author Information

Abstract

Objective

The purpose of this study is to determine the accuracy of implant placement in the edentulous jaw using computer planning and fully-guided mucosa-supported surgical template by Simplant software.

Methods

63 implants were placed in 9 patients (11 fully edentulous jaws), 26 implants were placed in upper edentulous jaw and 37 implants in lower edentulous jaw. Preoperatively, first, a cone beam CT was required for patients with radiographic template and radiographic template respectively. Therefore, the data of CBCT was inputted in Simplant software by DICOM format, followed by virtual implant planning. Hereafter, a mucosa-supported surgical template was designed by dentist and made by Masterilise company to allow implant placement using the template as a guide. To investigate the accuracy of implant placement, a postoperative CBCT scan was obtained and matched to the preoperative scan. The accuracy of implant placement was validated three-dimensionally including divations of implant shoulder, apical point, axial angulation and depth.

Results

The survival rate of 63 implamts for a 6 month to 10 year observation period was 100%. The mean divation of implant shoulder was 0.73 ± 0.53 mm, implant apical point was 1.15 ± 0.62 mm, implant depth was 0.95 ± 0.64 mm and implant axial angulationwas 4.10 ° ± 3.23°.

Conclusion

Divation between virtual and actual implant was existed and it should be considered preoperatively when virtual implant was planned to avoid injuring anatomic structure and keeping surgery safely. Correct manipulation during implant operation are helpful to decrease the divation of implant placement.

CLC number: R783.4 Document code: A Article ID: 2096-1456(2017)09-0575-07

References

【1】
【1】
 
 
Journal of Prevention and Treatment for Stomatological Diseases
Pages 575-581

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
LUAN L, XIAO H, LIU H, et al. The accuracy analysis of fully-guided mucosa-supported template based computer-assisted implant surgery. Journal of Prevention and Treatment for Stomatological Diseases, 2017, 25(9): 575-581. https://doi.org/10.12016/j.issn.2096-1456.2017.09.006

86

Views

0

Downloads

0

Crossref

0

Scopus

Received: 10 January 2017
Revised: 08 June 2017
Published: 20 September 2017
© 2017 by Editorial Department of Journal of Prevention and Treatment for Stomatological Diseases