AI Chat Paper
Note: Please note that the following content is generated by AMiner AI. SciOpen does not take any responsibility related to this content.
{{lang === 'zh_CN' ? '文章概述' : 'Summary'}}
{{lang === 'en_US' ? '中' : 'Eng'}}
Chat more with AI
PDF (17 MB)
Collect
Submit Manuscript AI Chat Paper
Show Outline
Outline
Show full outline
Hide outline
Outline
Show full outline
Hide outline
Full Length Article | Open Access

Effects of metal ion implantation (Fe, Ti, Zn and Zr) on mechanical properties, corrosion resistance and biocompatibility of WE43 Mg alloy

Lianhui Lia,bZhiqiang ZhangbDechuang ZhangaFugang Qia( )Yilong Daia( )Wenwen WeicXiaoping Ouyanga
School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
Key Lab of Electromagnetic Processing of Materials, Ministry of Education, Northeastern University, Shenyang 110819, China
Christian Doppler Laboratory for Interfaces and Precipitation Engineering CDL-IPE, Institute of Materials Science and Technology, TU Wien 1060, Austria
Show Author Information

Abstract

To improve the corrosion resistance of biodegradable Mg alloys, WE43 alloys were implanted with Fe, Ti, Zn and Zr ions at the same implantation dose. The surface morphology, valence state of elements, nano-hardness (NH), elastic modulus (EM), degradation rate and in vitro cell experiments of the modified WE43 alloys were systematically studied. A modified layer composed of Mg, MgO, the implanted elements and their oxides was formed on the modified alloys. Since high-speed metal ions caused severe surface lattice damage, the surface hardness of the substrate considerable increased. Electrochemical tests demonstrated a substantial enhancement in the corrosion resistance of the modified alloys via the implantation of Ti and Zr ions, resulting in a reduction of the corrosion current density to 88.1 ± 9.9 and 15.6 ± 11.4 µA cm−2, respectively, compared with the implantation of Fe and Zn ions. Biocompatibility tests showed that the implantation of Fe, Ti, Zn and Zr ions enhanced the anticoagulant and hemolytic resistance of the WE43 alloy. All surface-modified samples showed negligible cytotoxicity (0–1) at 12.5% extract concentration. Moreover, the alloys implanted with Fe, Ti and Zn ions significantly promoted proliferation of human umbilical vein endothelial cells (HUVEC) compared with the unmodified alloy. The results demonstrate that Ti ion implantation is the best choice for WE43 alloy modification to achieve outstanding corrosion resistance and biocompatibility.

References

【1】
【1】
 
 
Journal of Magnesium and Alloys
Pages 296-310

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
Li L, Zhang Z, Zhang D, et al. Effects of metal ion implantation (Fe, Ti, Zn and Zr) on mechanical properties, corrosion resistance and biocompatibility of WE43 Mg alloy. Journal of Magnesium and Alloys, 2025, 13(1): 296-310. https://doi.org/10.1016/j.jma.2024.05.005

70

Views

0

Downloads

78

Crossref

88

Web of Science

83

Scopus

1

CSCD

Received: 29 July 2023
Revised: 06 April 2024
Accepted: 07 May 2024
Published: 22 May 2024
© 2024 Chongqing University.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) Peer review under responsibility of Chongqing University