Full Length Article | Open Access

Experimental study on dynamic behavior of mechanically pumped two-phase loop with a novel accumulator in simulated space environment

Qingliang MENGa,b( ), Tao ZHANGc, Feng YUa,b, Yu ZHAOa,b, Zhenming ZHAOa,b, Zhenhua ZHOUa,b
Beijing Institute of Space Mechanics and Electricity, Beijing 100094, China
Beijing Key Laboratory of Advanced Optical Remote Sensing Technology, Beijing 100094, China
College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 200090, China

Peer review under responsibility of Editorial Committee of CJA.

Show Author Information

Abstract

Mechanically pumped two-phase loop (MPTL) which is a prominent two-phase heat transfer technology presents a promising prospect in thermal control for space payload. However, transient behavior of MPTL caused by phase-change and heat sources load-on/off in simulated space environment is rarely reported. In the present study, one MPTL setup was designed and constructed, and experimentally studied. Particularly, a novel two-phase thermally-controlled accumulator integrated with passive cooling measure and three capillary structures was designed as the temperature-control device. Dynamic behavior of the start-up, temperature control, and temperature adjustment were monitored; meanwhile, thermodynamic behavior within the proposed accumulator, the operating behavior as well as the heat and mass transfer behavior between the main loop and the accumulator were revealed. The results show that the fluid management function of the capillary structures for the novel accumulator is verified. The working point of the MPTL system can be adjusted by changing the temperature control point of the accumulator and it is little influenced by external heat flux and heat sources on/off. Pressure-drop oscillations which are manifested as fluctuations of temperature and pressure can be observed after phase changing due to the compressible volume within the accumulator and the negative-slope portion of the internal pressure.

References

【1】
【1】
 
 
Chinese Journal of Aeronautics
Pages 102-116

{{item.num}}

Comments on this article

Go to comment

< Back to all reports

Review Status: {{reviewData.commendedNum}} Commended , {{reviewData.revisionRequiredNum}} Revision Required , {{reviewData.notCommendedNum}} Not Commended Under Peer Review

Review Comment

Close
Close
Cite this article:
MENG Q, ZHANG T, YU F, et al. Experimental study on dynamic behavior of mechanically pumped two-phase loop with a novel accumulator in simulated space environment. Chinese Journal of Aeronautics, 2022, 35(12): 102-116. https://doi.org/10.1016/j.cja.2022.06.004

1450

Views

20

Crossref

18

Web of Science

20

Scopus

2

CSCD

Received: 17 June 2021
Revised: 14 July 2021
Accepted: 03 August 2021
Published: 08 June 2022
© 2022 Chinese Society of Aeronautics and Astronautics.

This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).